1510P & 1520P
Veris Drive Operating Instructions
Great Plains
| 118-732M | 4/4/19
97
2.
Press SETUP key. Press VEHICLE key. Set Primary
speed sensor to GPS.
3.
PRES SETUP key. Press CARD key. Set the
following:
•
Log Device:
None.
4.
Press SETUP key. Press APP RATE key. Set the
following:
•
Application Control:
On
•
Look Ahead:
On
•
Current Target File:
press Edit to view the files
you have on the card; select the one you wish to
use.
5.
Press SETUP key. Press CONTROLLER key. Select
controller as Rawson Accu-Rate. Press EDIT
SETTINGS. Set the following:
•
Number of Pulses/10 Revolutions:
500
•
Nominal Rate:
Divide the highest rate on your
recipe by 1.6. This is your Nominal rate. For
example, if your highest rate is 200,000 the
nominal is 125,000. If your highest rate is 32,
your nominal rate is 20.
•
Percent Rate Change:
set to 4%
•
Area Count:
Set to Standard
•
Stop Height:
Set to 8
•
Actual Rate Recording Method:
Set to
Sensor
•
Controller Time Delay:
Set to
4 sec
•
Application offset from GPS antenna
to your
Great Plains Mfg, Inc Meter
•
Serial Port:
Port 3
6.
Press SETUP key. Press PRODUCT key. Select
product and press EDIT SETTINGS. Set the
following:
•
Controller Device:
Rawson Accu-Rate
•
Calibration No for Actual Rate
: Set to 0
•
Actual Rate Scale Factor:
Set to 1.000
•
Target Rate Units:
Set to Seeds
•
Actual Rate Units:
Set to Seeds
•
Target Conversion Number
: If your recipe (.tgt
file) is written using the entire number as
the
desired rate, i.e. 30,000 seeds/acre on the recipe
means 30,000 seeds/acre is the desired rate,
enter a 1.000. If the recipe is written using a
different number, i.e. 30 on the recipe means a
population of 30,000, then you will need to enter
the conversion multiple - in that case 1,000.
Target Rate Increment:
Determines the increment
value by which you can change the manual
target
rate with each press of the arrow keys.