24
Function mode AIRPLANE
Function mode AIRPLANE
Fail Safe
Accessing the Programmable Mixing Function
1. Place the transmitter switch in the ON position.
2. Press the
Down
and
Select
keys simultaneously
to enter the Function mode.
3. Press either the
Up
or
Down
key until MIX 1
appears in the LCD.
Selecting the Master and Slave Mixing Channels
4. Press the (+) or (-) keys to select the master chan-
nel.
5. Press the
Select
key to move the cursor to the
slave channel position.
6. Press the (+) or (-) keys to select the slave channel.
7. Press the
Select
key once. The display will conti-
nue to show the current mixing channels at the
top of the LCD, but now an arrow will indicate the
current stick position (master) to be adjusted.
Setting the Mixing Values
8. While holding the master stick in the direction you
want to mix, press the (+) or (-) keys to increase or
decrease the mixing value for the slave channel. The
value in the LCD will change to display the current
mix value selected. Next, hold the master stick to the
other side to adjust the mix for the other direction.
Setting the Mixing Switch Activation
9. Press the
Select
key until the SW is highlighted.
The LCD with “ALWAYS ON“ indicates the current
switch that this mix is currently selected to always be
active (ON).
Mixing Operation and Switches
Each mixing program can be turned on and off by a
lever or switch. The levers and switches that can be
selected for program mixing are tabulated at the right
with their abbreviations appearing on the displayand
their corresponding positions.
Setting the Mixing Channel Offset
1. Press the Select key until offset is highlighted. The
display will show the current mixing channels at the
top of the LCD, with the word “OFFSET“ in the
center of the LCD. The value to the right is the
mixing Offset neutral point, currently 0.
2. A new value for the offset can be selected using the
(+) or (-) keys. This is the new neutral point for the
slave channel (Point that the mix is activated). Press
the
Clear
key to reset the value back to 0.
3. Press the
Down
and
Select
keys simultaneously
to exit the Programmable Mix function.
With a little practice, programmable mixing will become
easier to understand. Mixing is inly limited by your
imagination.
Fail Safe
The Fail Safe/Hold function is available only when you
use the mx-12 transmitter in PCM modulations. This
function is designed to help minimize damage to your
aircraft during a loss of signal to the receiver. The ser-
vos either assume the fail-safe presets or hold their last
good signal position.
As noted earlier, if you are in the PPM modulation, the
Fail-Safe/Hold function is not applicable. Therefore,
the Fail-Safe/Hold function will not appear on your LCD
screen menu while in the PPM mode. Refer to the Mo-
dulation Selection section for more information pertai-
ning to the broadcast signal of your mx-12 transmitter.
Note:
The throttle fail safe position is defaulted to the
idle position for added safety.
Fail Safe Side Display
Channel being programmed
TH Throttle
RU Rudder
AI Aileron
GE Gear
EL Elevator
FL Flap
Hold Side Setup Display
Go to Servo Travel
Screen
Go to Programab-
le Mixing menu
Change highlighted
selection
Change from servo
hold to stick selection
(F.S.
HOLD)
Invoke stick selection
Accessing the Fail Safe Function
1. Place the transmitter power switch in the ON positi-
on.
2. Access the Function mode. To do so, press the
Down
and
Select
keys simultaneously. Press
either the
Up
or
Down
key until
FAIL SAFE
ap-
pears in the upper portion of the LCD screen.
3. Use the
Select
key to highlight the servo function to
set.
4. Use the (+) or (-) keys to toggle between servo hold
or setting the servo position.
5. When using the servo setting position, move the
corresponding control stick to the position where you
want the servo if the radio enters into the fail safe
mode. Press the Clear key to have the transmitter
memorize all stick position.
6. Repeat steps 4 and 5 intil all six controls have been
set.
7. Access the
SERVO TRAVEL
screen by pressing the