Chapter 2 - Installation
2.5.5 Open circuit/Voltage level
Leave the circuit open or apply a DC voltage to the inputs (respect polarity). If the circuit is
open, the function is Active (or Inactive). If the voltage is high (4 to 24 V) the function is Inactive
(or Active).
The function state depends on the selection in the
INSTALL
>
SIGNALLING
INPUT
menu:
Menu setting
Input is open:
Input is 4 to 24V:
OH (open-high)
Function is Active
Function is Inactive
HO (high-open)
Function is Inactive
Function is Active
ISO 1a
Open/
4..24 V
DC
Open/
4..24 V
DC
Open/
4..24 V
DC
ISO 1b
On-Air (Tally) 1a
On-Air (Tally) 1b
Call 1a
Call 1b
ISO in ext. send (pin 3)
ISO in ext. return (pin 11)
On-Air in ext. send (pin 4)
On-Air in ext. return (pin 12)
Call in ext. send (pin 5)
Call in ext. return (pin 13)