![GRASS VALLEY XCU UXF Fiber Series User Manual Download Page 20](http://html1.mh-extra.com/html/grass-valley/xcu-uxf-fiber-series/xcu-uxf-fiber-series_user-manual_2257950020.webp)
20
XCU UXF Fiber Series XF Transmission Fiber Base Station User’s Guide (v1.3)
Chapter 2 - Installation
2.5.2 Dry contact with multiple XCUs
This is an example of an On Air signalling with multiple XCUs using a common contact.
☞
Note
☞
Note
Use either Send or Return only, but do not mix.
If a contact is closed, the corresponding function is Active or Inactive, depending on the
selection in the
INSTALL
>
SIGNALLING
INPUT
menu:
Menu setting
Input is shorted:
Input is open:
LH (low-high)
Function is Active
Function is Inactive
HL (high-low)
Function is Inactive
Function is Active
On-Air (Tally) 1
On-Air (Tally) 2
On-Air (Tally) n
Common
External On-Air signalling
(common contact)
On-Air in ext. send (pin 4)
Signalling connector
On-Air in ext. return (pin 12)
Base Station 1
Signalling connector
Base Station 2
Signalling connector
Base Station n
On-Air in ext. send (pin 4)
On-Air in ext. return (pin 12)
On-Air in ext. send (pin 4)
On-Air in ext. return (pin 12)
Menu setting
Input is shorted:
Input is open:
LH (low-high)
Function is Active
Function is Inactive
HL (high-low)
Function is Inactive
Function is Active