K2 Storage System Instruction Manual
July 3, 2007
Chapter 3 Installing the Level 2R Storage System
Networking for Level 2R
Use the topics in this section to configure the Gigabit Ethernet (GigE) network for the
Level 2R storage system.
•
“Networking requirements” on page 90
•
•
“Setting up host tables” on page 92
•
“Testing the control network” on page 93
Networking requirements
Required networking strategies for a Level 2R (a redundant K2 Storage System) are
as follows:
• Four networks:
• Media network A — Exclusively for iSCSI traffic. For failover purposes, this
network restricts traffic between an “A” media port on a K2 Media Client and
the “A” K2 Media Server with the role of media file system/database server.
• Media network B — Exclusively for iSCSI traffic. For failover purposes, this
network restricts traffic between a “B” media port on a K2 Media Client and the
“B” K2 Media Server with the role of media file system/database server.
• Streaming/FTP network — For media transfers and FTP traffic.
• Control network — For all other non-streaming, non-iSCSI traffic.
• Networks must be on separate subnets.
• The real-time iSCSI traffic of the media networks (A and B) is kept separate from
traffic that is not real-time, such as that of the streaming/FTP network and the
control network. This separation is provided by dedicated Gigabit ports, cables,
and by a dedicated VLAN on the HP GigE switch or by separate switches.
• K2 Media Servers have a dedicated FTP port. If the server takes the role of FTP
server, make a dedicated FTP connection to the FTP port.
• While control and FTP traffic is each on its own subnet, it is not required that each
type of traffic has its own VLAN on GigE switches. For example, you make both
FTP and control connections to the “control” ports (DEFAULT_VLAN) on the HP
GigE switch.
• Static IP addresses are required for the media networks on K2 Storage System
iSCSI devices. This includes K2 Media Servers, generic iSCSI clients (such as
Aurora Edits), and K2 Media Clients.
• Machine names (host names) assigned to each K2 device.
• Host tables (hosts files) provide name resolution on each K2 Media Client, iSCSI
client, and K2 Media Server.
• IP addresses for FTP/streaming ports must have name resolution such that
hostnames are appended with the “_he0” suffix. You can use host tables (as in
“Setting up host tables” on page 92
) or another mechanism to provide the name
Summary of Contents for K2 BASECAMP EXPRESS
Page 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Page 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Page 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Page 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Page 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Page 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Page 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...