K2 Storage System Instruction Manual
July 3, 2007
Chapter 3 Installing the Level 2R Storage System
Power on the L2 RAID chassis
Your preparations for L2 RAID storage are now complete.
Preparing K2 Storage System clients
Any devices that function as iSCSI clients to the K2 Storage System must be prepared
with the following requirements:
• One or more connections to the control network.
• A static IP address for the control network.
• For a Level 2R, 3R or other redundant K2 Storage System, K2 Media Clients have
one connection to the A media (iSCSI) network and one connection to the B media
(iSCSI) network. Other iSCSI clients with just one media port connect to either the
A or the B network.
Additional steps that are required for Aurora Edits include the following:
• Implement Aurora Edit security features.
POWER
SERVICE
K2
RAID STORAGE
!
Power Cords
(115V/2
3
0V)
Power-up Verification
Re
a
dy LED
s
on RAID controller
s
a
re
s
te
a
dy ON.
Front p
a
nel Power LED i
s
ON,
S
ervice LED i
s
OFF
a
fter
a
pproxim
a
tely
3
min
u
te
s
.
Refer to the L2 RAID Instruction M
a
nu
a
l if there i
s
a
pro
b
lem.
Power LED
Ready
LED
Ready
LED
Connect power cords, and turn on power as shown.
You must power-up any RAID Expansion chassis
prior to, or at the same time as the RAID Controller
chassis. Verify power-up as shown.
Service LED
Summary of Contents for K2 BASECAMP EXPRESS
Page 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Page 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Page 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Page 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Page 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Page 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Page 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...