Configuring Level 3 RAID chassis network and SNMP settings
Configuring Level 3 RAID chassis network and SNMP settings
Through Storage Utility you can configure the following settings on a RAID chassis:
• IP address
• Subnet mask
• Gateway Address
• SNMP trap destinations
For the Level 3 RAID chassis, network and SNMP settings are set and stored on the
RAID controller. Therefore, if the RAID chassis has two controllers, each controller
must be configured separately, as in the following procedure.
1. In the K2 System Configuration application tree view, open the node for a K2
Media Server and select the
File System Server
node to open its property page. On
the property page click
Launch Storage Utility
. Storage Utility opens.You can now
configure the network settings on the controller connected to the selected K2
Media Server.
2. In the Storage Utility, right-click the icon for a RAID controller and select
Configuration | Network Properties
. The Network Settings dialog box opens.
3. Enter network settings.
4. For each SNMP manager to which you want to send SNMP trap messages, enter
the IP address of the PC hosting the manager. For monitoring with NetCentral,
enter the IP address of the NetCentral server PC.
Summary of Contents for K2 BASECAMP EXPRESS
Page 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Page 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Page 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Page 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Page 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Page 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Page 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...