Chapter 2 Installing the Level 2 Storage System
• On the external storage K2 Media Client, the two control GigE ports are configured
as a team. The control team shares a single IP address. Do not attempt to un-team
the control ports. On the Level 2 K2 Storage System, only one control port is
connected, as control team redundancy is not supported.
• On the external storage K2 Media Client, the two media (iSCSI) GigE ports are not
teamed. On the Level 2 K2 Storage System, only one media port is connected, as
iSCSI redundancy is not supported.
Also refer to
“About networks and FTP” on page 318
and
Ethernet switches” on page 388
Use the following procedures as necessary to implement your networking strategies.
NOTE: It is recommended that you configure Media network (iSCSI) IP addresses
and Streaming network IP addresses using the K2 System Configuration
application, rather than doing so on the local machine using standard Windows
procedures.
Networking tips
• Before beginning network configuration, determine the IP addresses and names
needed for the machines in your K2 system. Work with the network administrator
at your facility to have those IP addresses and names available for your use.
• Establish a consistent convention for machine names and IP addresses. It is
recommended that you embed a root name or other unique identifier for this
particular K2 Storage System in the computer name. Also, a common convention
for IP addresses is to use a numerical pattern or sequence in the IP addresses to
indicate device-types and/or ports, as in the following example:
NOTE: This example assumes a subnet mask of 255.255.255.0
Example of Level 2 names and IP addresses
Computer
name
Device type
Streaming network
addresses
Control network
addresses
Media network
addresses
Comments
root_server_1
K2 Media
Server
192.168.101.11
a
a.
This IP address must resolve to hostname
root_server_1_he0
192.168.100.11
192.168.99.11 —
192.168.99.12 —
root_raid_1
RAID
—
192.168.100.51
—
—
root_gige_1
GigE switch
—
192.168.100.61
—
—
root_cppc_1
Control point
PC
—
192.168.100.81
—
—
root_client_1
iSCSI client
—
192.168.100.111
192.168.99.111
—
root_client_2
iSCSI client
—
192.168.100.121
192.168.99.121
root_client_3
iSCSI client
—
192.168.100.131
192.168.99.131
root_client_4
iSCSI client
—
192.168.100.141
192.168.99.141
Summary of Contents for K2 BASECAMP EXPRESS
Page 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Page 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Page 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Page 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Page 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Page 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Page 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...