- 63 -
Symptom
Check items
Solutions
Sometimes, F-Mark2 can not be
insert the media to the
CE7000-40 correctly.
The media has been curled or
shrank in the unstable operating
environment.
Changes temperature or
humidity might be cause the
media curled or shrunk.
Use F-Mark2 in the stable
operating environment.
The media can not be pick up one
by one due to the static
electricity.
Remove the static electricity from
the media to be used before
using.
The connection position between
F-Mark2 and CE7000-40 is
shifted due to vibration during
operation.
Use the F-Mark2 on the stable
working table.
The inputted values or changed
settings in the iMark Plus
software are not reflected to the
cutting.
The “Cut Test” in the iMark Plus
software has not been
performed, after inputting the
values or changing the settings.
After inputting the values or
changing the settings in the iMark
Plus software, make sure to
perform the “Cut Test” to enable
the inputted values or changed
settings.
The X cutting position does not
align.
The left side Pinch Roller has
been shifted after performed
calibration.
Set the position of left side Push
Roller to correct position, and
then perform the calibration
again. Refer to “How to initialize
F-Mark2 and CE7000-40” and
“How to calibrate F-Mark2”.
The Y cutting position does not
align.
The angle of the camera has
been changed after performed
calibration.
Adjust the angle of camera to
correct angle, and then perform
the calibration again. Refer to
“How to adjust the angle of the
Camera” and “How to calibrate
F-Matk2”