Appendix B - Alarms
92
3A2776K
*MEA
X
*MEB
X
Maintain Dosing Valve.
Always, if
enabled
Dosing valve usage exceeds
user-set limit. Maintenance due.
Service dosing valve. See pump
manual listed on page 4.
*MGP
X
Maintain Air Filter.
Always, if
enabled
Air filter exceeds user-set limit.
Maintenance due.
Service main air filter and control
filter regulator.
P1AX
P1BX
Pressure Low.
Spray,
Pump
Test, Leak
Test
Fluid pressure is below 1000 psi (7
MPa, 70 bar) for spray mode or
below 1500 psi (10.3 MPa, 103
bar) to test modes.
Increase main air regulator.
*P2AX
*P2BX
Pressure Exceeded
Advisory Limits.
Spray
Pressure exceeded high or low
advisory limits for more than 15
seconds.
Same as P5AX or P5BX.
P4AX
P4BX
Pressure High.
Always
Fluid pressure is above maximum.
Decrease main air regulator.
P4RE
Pressure High.
Recirculati
on
Pressure is above maximum
advisory limit of 3000 psi (21 MPa,
210 bar) on A side.
Decrease pump air regulator
pressure.
P5RE
Pressure High.
Recirculati
on
Pressure is above maximum
warning limit of 5200 psi (35.9
MPa, 359 bar) on A side.
Decrease pump air regulator
pressure.
*P5AX
*P5BX
Pressure Exceeded Alarm
Limits.
Spray
Pressure exceeded high or low
alarm limits for more than 15
seconds.
Adjust pump pressure regulator,
change tips, or adjust target set
point.
P6AX
P6BX
Pressure Sensor Failure; No
Signal.
Always
Pressure sensor or cable is bad on
the side indicated.
Replace sensor and cable
assembly. See XM PFP repair
manual.
P9AX
A Pump Pressure is
Abnormally Low Compared
to B Pump Pressure.
Spray
A air motor is icing causing
restriction and lower fluid pressure.
Open the air motor de-ice bleed air
controls. Allow ice to melt. Dry
compressed air. Heat compressed
air.
Use a smaller tip.
A pump is binding.
Repair lower. See XM PFP repair
manual.
A motor is binding.
Repair air motor. See XM PFP
repair manual.
P9BX
B Pump Pressure is
Abnormally Low Compared
to A Pump Pressure.
Spray
B air motor is icing causing
restriction and lower fluid pressure.
Open the air motor de-ice bleed air
controls. Allow ice to melt. Dry
compressed air. Heat compressed
air.
Use a smaller tip.
B pump is binding.
Repair lower. See XM PFP repair
manual.
B air motor is binding.
Repair air motor. See XM PFP
repair manual.
Alarm
Code
Alarm Problem
When
Active
Cause
Solution