Setup
22
3A2776K
e.
For Non-Hazardous Location Models,
Connect heater power cables (e) for the tank
heater and the flush heater to the terminal
blocks. See F
For Hazardous Location Models,
Connect heater
power cables (e) for the tanks heater the flush heater to
the terminal blocks. See F
. 17.
4.
Connect the fluid circulation return hoses.
-
The 1/2 in. circulation hose from the dosing
valve connects to the side of the A tank.
-
The 3/8 in. circulation hose from the dosing
valve connects to the side of the B tank.
Systems that will be used for 1:1 mix ratio materials
need to change some fittings and circulation hoses. Use
parts from kit 24X461 (supplied with your machine). See
manual 334939 for instructions.
F
IG
. 16
3UHVVXUH7DQN
6\VWHP)OXVK
+HDWHU
+HDWHU
PS1
TB8
TB9
TB10
TB1
1
TB12
TB9
TB10
TB1
1
TB12
&LUFXLW%UHDNHU
A
B
Hose
Tank
Flush
*URXQG
%DU
WLD
e
e
F
IG
. 17
3UHVVXUH7DQN
6\VWHP)OXVK
*URXQG
%DU
&LUFXLW%UHDNHU
WLE
+HDWHU
+HDWHU
e
e