Appendix B - Alarms
3A2776K
93
QDAE
Dosing Size A Alarm
Spray
The fluid dosing size is greater
than 45 cc when fast dosing is
turned off.
Decrease the air motor velocity with
a smaller tip or increase ‘B’
restriction.
The fluid dosing size is greater
than 30 cc when fast dosing is
turned on.
Decrease the air motor velocity with
a smaller tip or increase ‘B’
restriction.
*QPD
X
Pot Life Timer Expired.
Mixed Fluid Will Cure in
Hoses, Mixer, and Gun.
Spray
Have not sprayed enough volume
to keep fresh mixed fluid in the
integration hose, mixer, whip hose,
and spray gun.
Spray fluid, or flush. Resets when
you leave spray mode. See
page 44.
QTAE
Dosing Size A Advisory
Spray
The fluid dosing size is greater
than 35 cc when fast dosing is
turned off.
Decrease the air motor velocity with
a smaller tip or increase ‘B’
restriction.
The fluid dosing size is greater
than 20 cc when fast dosing is
turned on.
Decrease the air motor velocity with
a smaller tip or increase ‘B’
restriction.
R1BE
Ratio Low B (Under Dose
B); System Delivering Not
Enough B Component.
Spray
B dosing valve will not open.
Check for air signal to valve.
B mix manifold valve closed.
Open green mix manifold valve.
Pump filter plugged on B side.
Use alternate 30 mesh screen. See
manual 311762 for part number.
Clean B pump outlet filter. See
manual 311762.
R4BE
Ratio High B (Overdose B);
System Delivering Too
Much B Component.
Spray
B Dosing valve not closing.
Perform Pump Test to test for
leakage. See
Test and Calibration for Ratio by
Weight Mode
Loosen valve packing nut. See XM
PFP repair manual.
Check air signal at valve top
Repair valve or air solenoid. See
XM PFP repair manual.
Pump filter plugged on A side.
Clean filter. See manual 311762.
Use alternate 30 mesh screen. See
manual 311762 for part number.
Inlet air dropping below 80 psi
(0.55 MPa, 5.5 bar) while spraying.
B dosing valve not closing
correctly.
Check air filters. See XM PFP
repair manual.
Use larger air hose.
Use larger compressor.
Use smaller gun tips or less guns to
reduce flow rate.
Solenoid air regulator set below 80
psi (0.55 MPa, 5.5 bar)
Adjust air regulator.
Alarm
Code
Alarm Problem
When
Active
Cause
Solution