Operation Using a Programmable Logic Controller (PLC)
Network
Network
Network
Output
Output
Output ID
ID
ID
Modbus
Modbus
Modbus
Register
Register
Register
Parameter
Parameter
Parameter Name
Name
Name
Data
Data
Data Type
Type
Type
Units
Units
Units
Range
Range
Range
0 = No Events
0027
42002
Event Flag
uint32
NONE
1 = New Event
0028
42004
Actual Mix
Flow/Pressure
uint32
cc/min
or PSI
1 – 1600
0029
42006
Actual Mix Ratio
uint32
NONE
0 – 5000
0030
42008
Actual Mix Potlife
Remaining
uint32
sec
0 – 59940
0 = Gun not triggered
0031
42010
Gun 2 Trigger Status
uint32
NONE
1 = Gun triggered
0 = Off
1 = Standby
2 = Busy
3 = Flushing
0032
42012
Pump 3 Status
uint32
NONE
4 = Priming
0 = Off
1 = Standby
2 = Busy
3 = Flushing
0033
42014
Pump 4 Status
uint32
NONE
4 = Priming
0034
42016
Pump 3 Material
uint32
NONE
0 – 40, 61
0035
42018
Pump 4 Material
uint32
NONE
0 – 40, 61
0036
42020
Actual Pump 3 Flow
Rate
uint32
cc/min
0 – 800
0037
42022
Actual Pump 4 Flow
Rate
uint32
cc/min
0 – 800
0038
42024
Actual Pump 3Fluid
Pressure
uint32
PSI
0 – 1500
0039
42026
Actual Pump 4 Fluid
Pressure
uint32
PSI
0 – 1500
0040
42028
Active Recipe Number
uint32
NONE
0 – 30, 61
0041
42030
Active Recipe Material
A
uint32
NONE
1 – 32, 61
0042
42032
Active Recipe Material
B
uint32
NONE
33 – 40, 61
0043
42034
Active Recipe Material
A Flush Sequence
uint32
NONE
1 – 5
0044
42036
Active Recipe Material
B Flush Sequence
uint32
NONE
1 – 5
0045
42038
Active Recipe Ratio
Set Point
uint32
NONE
0 – 5000
0046
42040
Active Recipe Potlife
Time Set Point
uint32
min
0 – 999
0047
42042
Job Number
uint32
NONE
0 – 9999
0048
42044
Job A Sprayed Volumn
unit32
cc
0 – 999999999
0049
42046
Job B Sprayed Volume
unit32
cc
0 – 999999999
3A4486D
33