Air/Solvent
Air/Solvent
Air/Solvent Chop
Chop
Chop
Air/Solvent Chop replaces the standard Gun Purge
Time parameter on the Flush screen. Instead the
purge is split into three phases: First Purge, Chop,
and Final Purge. The Chop Phase will always start
with Air and each phase has multiple configuration
parameters.
Figure 52 Flush Screen with Air/Solvent Chop
First
First
First Purge
Purge
Purge
Select the material to be either Air or Solvent and
the length of time for the first purge phase, which
dispenses only the material selected.
Air
Air
Air Chop
Chop
Chop
Set the air chop duty cycle for the chop phase.
Solvent
Solvent
Solvent Chop
Chop
Chop
Set the solvent chop duty cycle for the chop phase.
Total
Total
Total Chop
Chop
Chop
Set the length of time for the chop phase. The
system will switch between air and solvent pulses
according to the duty cycles set for the length of the
Total Chop time.
Final
Final
Final Purge
Purge
Purge
Select the material to be either Air or Solvent and
the length of time for the final purge phase, which
dispenses only the material selected.
Figure 53 Air/Solvent Chop Timing Diagram
80
3A4486D