The PD2K has PLC Diagnostic Screens built into the software that assist in the system integration process. See
.
NOTE:
NOTE:
NOTE: The PD2K Dual Panel system has identical network register blocks for the two Mix Units. All registers are
shown with indices for Mix Unit #1 and Mix Unit #2, respectively.
ProMix
ProMix
ProMix PD2K
PD2K
PD2K Network
Network
Network Outputs
Outputs
Outputs
The ProMix PD2K Network Outputs are Read-Only and should be treated as inputs to a PLC or other networking
device. These registers provide various system and component status, measurement, and set point values. See
Network Output Data Map (Read Only), page 31
.
OUTPUT
OUTPUT
OUTPUT REGISTER
REGISTER
REGISTER 00
00
00 and
and
and 26:
26:
26: Current
Current
Current System
System
System Mode
Mode
Mode
The Current System Mode register contains a number that indicates the current operation mode of the PD2K system.
Number
Number
Number
Operation
Operation
Operation Mode
Mode
Mode
Description
Description
Description
1
Pump Off
The pumps are currently powered down
and the Mix Unit is not in operation.
2
Recipe Change
The Mix Unit is in the process of a color
change sequence.
3
Recipe Change: Purge A
The Mix Unit is purging material A as part
of a recipe change.
4
Recipe Change: Purge B
The Mix Unit is purging material B as part
of a recipe change.
5
Recipe Change: Fill
The Mix Unit is filling the hose from the
remote valves to the mix manifold with
material as part of a recipe change.
6
Mix Fill
The Mix Unit is mixing material at ratio
through the mix manifold and out the gun.
7
Mix
The Mix Unit is currently mixing/spraying
material.
8
Mix Idle
The Mix Unit has paused mix operation
due to the absence of a gun trigger signal.
9
Purge A
The Mix Unit is purging material A while
in Standby.
10
Purge B
The Mix Unit is purging material B while
in Standby.
11
Standby: Mix Ready
The Mix Unit has a valid recipe loaded
out to the gun.
12
Standby: Fill Ready
The Mix Unit has a valid recipe loaded in
the pumps, but not in the gun.
13
Standby: Mix Not Ready
The Mix Unit requires that a recipe
change operation be completed.
14
Standby: Alarm
The Mix Unit has an active alarm.
15
Line Filling/Flushing
The Mix Unit is filling/flushing a color
change hose between the outlet valves
and remote valves.
16
Pump Prime/Flush
The Mix Unit is priming/flushing one of
the pumps.
17
Maintenance/Calibration
The Mix Unit is currently performing a
calibration or maintenance procedure.
18
Mix: Solvent Push
The Mix Unit is currently mixing/spraying
with solvent push engaged.
3A4486D