Calibrate
Calibrate
Calibrate Screen
Screen
Screen 3
3
3
Calibrate Screen 3 initiates a calibration of an
accessory solvent meter. During the test, the Volume
Verification screen will appear.
The meter and lines must be primed with
solvent before doing the calibration. See
Solvent Meter Calibration, page 97
for complete
instructions.
To initiate the calibration, press the Volume Check
button.
The screen displays the volume dispensed. Enter
the amount of solvent dispensed in the Measured
Volume field, or press
to end the test.
After the Measured Volume is entered, the Accept
Calibration window will appear. Press
to accept
the calibration. Press
to cancel the calibration
and retain the previous K-factor.
Press and hold the Reset button
for 1-2
seconds to reset the volume counter.
Figure 71 Calibrate Screen 3
Figure 72 Enter Measured Volume of Solvent
Figure 73 Accept Calibration
3A4486D
89