Run Screen 1 (Electrostatic Readings)
To reduce the risk of electric shock, do not use the
Electrostatic Controller readings to determine if
your system is discharged. The controller will only
display the voltage while the applicator’s power
supply is operating. Follow the Fluid Voltage
Discharge and Grounding Procedure described in
the applicator manual.
Run Screen 1 is the main screen for the electrostatic
applicator. This screen shows the active Preset (A5)
and set points for voltage (A1) and current (A2). The
screen also displays actual values for kV and μA
when the electrostatics are active/triggered. Actual
values are displayed in green.
Use this screen to set the voltage (A1) and current
(A2) set points for each Preset. The set point is
displayed in black. Set points can be changed by
pressing the corresponding
and
keys when
actual values are displayed. The set points also can
be viewed by pressing
or
once.
NOTE: When in REMOTE operation, these values
cannot be changed using the display keys.
Press
to select the Preset (P000 — P250).
Press
to acknowledge error codes.
Location
Description
Units
Range
Default
A1
Black: Voltage Setpoint
Green: Spraying Voltage
kV
0–100kV
(solventborne)
0–60kV
(waterborne)
0kV
A2
Black: Current Setpoint
Green: Spraying Current
μA
0–150 μA
0μA
A3–A4
None
—
—
—
A5
Active Preset, error diagnosis, or status —
—
—
3A3657C