PARAMETERS
Setup
Screen
Display
(A1)
Value
Description
Display (A3) Values
Display
(A4)
Value
6
P06
CAN Purpose ID
Use to set the purpose ID for CAN communication.
0–32
0 (default)
Pid
7
P07
Log level
Display A2: LoG
Use to designate how much information is logged
in the system.
0–5
2 (default)
LoG
CONFIGURATION
Setup
Screen
Display (A1)
Value
Description
Display (A2) Values
8
C0
Arc detection averaging interval Δt [sec]
Use to set the time interval that the controller will use
to calculate the dynamic arc.
0.01 – 1.00 by 0.01
0.10 (default)
9
C1
Arc detection blanking time setpoint [sec]
Use to set the amount of time after turning on the high
voltage during which arc detection is suppressed.
0.0 – 30.0 by 0.1
0.5 (solventborne default)
10.0 (waterborne default)
10
C2
Discharge timer setpoint [sec]
Use to set the time needed to fully discharge after
turning off the electrostatics.
5.0 – 120.0 by 0.1
5.0 (solventborne default)
60.0 (waterborne default)
11
C3
Transition Time Interval [sec]
Use to set the interval of transition time between
electrostatic setpoints.
0.0 – 5.0 by 0.1
0.0 (default)
42
3A3657C