8
308770
Installation
Installing the Pump Module
The pump module consists of the pump mounted on
the pump bracket, the air controls, back pressure
regulator, hoses, and plumbing.
NOTE:
Refer to Fig. 1 on page 7, and to the Dimen-
sion drawing on page 26 and the Mounting Hole Lay-
outs on page 27.
1.
Ensure that the wall is strong enough to support
the weight of the pump and accessories, heater,
fluid, hoses, and stress caused during pump
operation.
2.
Mount the pump near a site with at least 9 ft (2.8
m) overhead clearance for the elevator when fully
raised.
3.
Position the bracket mounting plate (37) on the
wall so the edge with the hook is facing up. Mount
the plate so the top edge is 4 to 5 ft (1.2 to 1.5 m)
above the floor. Check that the plate is level. Mark
two holes on the wall, using the plate as a tem-
plate. Drill two holes and attach the plate with 1/2
in. bolts and washers.
4.
Using two people, hang the pump module on the
bracket mounting plate (37). Have one person hold
the module in place while the other checks that the
pump bracket (22) is level. Mark four holes on the
wall, using the pump bracket as a template. Re-
move the pump module.
5.
Drill four holes in the wall.
WARNING
The pump bracket (22) must be bolted to the wall
with four bolts. Do not simply hang the pump
bracket on the bracket mounting plate (37).
6.
Lift the pump module back into position, hang it on
the bracket mounting plate (37), and bolt the pump
bracket (22) to the wall. Use 1/2 in. bolts and
washers to mount the pump module to the wall.
Use bolts that are long enough to keep the pump
bracket (22) from vibrating during operation.
Summary of Contents for President 232090