Operation
Pressure Relief Procedure
WARNING
PRESSURIZED EQUIPMENT HAZARD
The system pressure must be manually relieved to
prevent the system from starting or spraying acci-
dentally. To reduce the risk of an injury from acci-
dental spray from the gun, splashing fluid, or
moving parts, follow the
Pressure Relief Proce-
dure
whenever you:
D
are instructed to relieve the pressure,
D
stop spraying,
D
check or service any of the system equipment,
D
or install or clean the spray nozzle.
WARNING
HOT SURFACE HAZARD
Do not touch the heater while it is oper-
ating. Allow the heater to cool for at least
10 minutes before flushing or servicing
it.
WARNING
FIRE AND EXPLOSION HAZARD
Do not
plug in or unplug a power cord in
any area containing flammable fluids or
fumes, to avoid fire or explosion result-
ing in serious injury.
1.
Disconnect the electric power to the heater (201).
2.
Circulate the fluid for at least 10 minutes to cool
the heated fluid and the heater.
3.
Close the red-handled bleed-type master air valve
(11h, required in your system). See Fig. 6.
4.
Place the drain hose (42) into a waste container.
Turn the 3-way recirculation valve (19) to the drain
position.
5.
Trigger the gun at the last gun station to relieve
fluid pressure. Maintain firm metal-to-metal contact
between the gun and a grounded waste pail.
Repeat for all gun stations.
6.
Open the drain valve (208) to relieve fluid pressure
which may be trapped in the pump or hose.
If you suspect that pressure is not fully relieved after
following the steps above, wrap a fitting near the pump
outlet with a rag, and slowly and carefully loosen the
fitting to relieve pressure. Be careful to protect your
eyes from splashing.
Packing Nut
Before starting, fill the packing nut (H) 1/3 full with
Graco Throat Seal Liquid (TSL) or compatible solvent.
See Fig. 6.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure
at left.
The packing nut is torqued at the factory and is ready
for operation. If it becomes loose and there is leaking
from the throat packings,
relieve pressure, then torque
the nut to 34–40 N
S
m (25–30 ft-lb). Do this whenever
necessary. Do not overtighten the packing nut.
Flush the Pump Before First Use
The pump is tested with lightweight oil, which is left in
to protect the pump parts. If the fluid you are using
may be contaminated by the oil, flush it out with a
compatible solvent. See
Flushing
on page 18.