Technical Data
Part No. 232090, Series A, 3:1 President heated circulation package
Category
Data
Maximum fluid working pressure
300 psi (2.1 MPa, 21 bar)
Maximum air input pressure
100 psi (0.7 MPa, 7 bar)
Ratio
3:1
Maximum heater voltage and
amperage
120 VAC, 19.2 Ampere
Maximum operating temperature
150
_
F (66
_
C)
Weight
114 lb (52.7 kg)
Wetted parts
Pump:
See pump manual 308793.
Fluid Heater:
See heater manual 309524.
Back Pressure Regulator:
See back pressure regulator manual 308401.
Fluid Filter:
See filter manual 308918.
Back-Geared Agitator:
See agitator manual 308609.
Fluid Hoses:
Nylon
Sound Pressure Levels (dBa)
(measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
Air Motor
40 psi (0.28 MPa, 2.8 bar)
70 psi (0.48 MPa, 4.8 bar)
100 psi (0.7 MPa, 7 bar)
President
73.6 dB(A)
78.3 dB(A)
80.9 dB(A)
Sound Power Levels (dBa)
(tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
Air Motor
40 psi (0.28 MPa, 2.8 bar)
70 psi (0.48 MPa, 4.8 bar)
100 psi (0.7 MPa, 7 bar)
President
87.4 dB(A)
92.1 dB(A)
94.6 dB(A)
Performance Chart
0
50
100
150
200
250
300
350
400
0
2
4
6
8
10
12
14
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
PUMP
OUTLET PRESSURE
AIR CONSUMPTION
12
25
37
49
61
73
CPM
86
8
15
23
30
38
46
54
GPM
l/min
30
20
10
0
1.96
0.84
0.28
CFM
m
3
/min
70
0.56
40
1.12
50
1.40
60
1.68
A
B
C
A
B
C
1.4, 14
0.7, 7
PSI
1.05, 10.5
0.35, 3.5
1.7, 17
2.45, 24.5
MPa, BAR
2.1, 21
2.8, 28
To find Outlet Pressure
(MPa/bar/psi) at a specific
delivery (liter/min or gpm) and operating air pressure
(MPa/bar/psi):
1.
Locate desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected fluid outlet pressure curve (black
curves). Curve slopes from left to right.
Follow left to scale and read outlet pressure.
To find Pump Air Consumption
(m
3
/min or
CFM/min) at a specific delivery (liter/min or gpm)
and operating air pressure (MPa/bar/psi):
1.
Locate desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected air consumption curve (dashes).
Curve slopes from right to left. Follow right to
scale and read air consumption.
A
0.7 MPa, 7 bar (100 psi) air pressure
B
0.49 MPa, 4.9 bar (70 psi) air pressure
C
0.28 MPa, 2.8 bar (40 psi) air pressure
Summary of Contents for President 232090