Graco Motor Control Operation (BLDC Models)
Graco Motor Control Menu Quick Reference
G100 (View Events)
Displays the last 20 system event codes.
G101 (View or Reset Batch Volume)
Displays the batch volume that has been dispensed.
G102 (View Life Total)
Displays the total number of pump cycles for the
life of the pump.
G130–G132 (View Maintenance Counters 1, 2, 3)
Displays the number of pump cycles since the last
maintenance.
G200 (Set Control Mode)
0 = Flow Control (default)
1 = Batch C ontrol
G201 (Set Flow Units)
0 = cpm, default
1 = gpm
2 = lpm
G203 (Set Pump K-Factor)
Range: 52–785 cc/cycle
Default: 523
G204 (Enable Max Power)
0 = Disabled (Default)
1 = Enabled
G205 (Input Current Limit)
0 = 12A (Default)
1 = 16A
G206 (Set Leak Detection Type)
0 = Disabled or leak sensor not installed (Default)
1 = Deviation
2 = Alarm
G207 (Set Maximum Acceleration)
Range: 1-300 seconds
Default: 20 seconds
G208 (Set Maximum Deceleration)
Range: 1-300 seconds
Default: 1 second
G209 (Configure External Control)
0 = Disabled (Default)
1 = Stop Only (Manual Start)
2 = Start/Stop (Full Remote)
3 = Full Control (Both Start/Stop and Flow)
G210 (Set or Disable Password)
Range: 1-99999
99999 = display G400 menu
Default: 0 (password disabled)
G212 (Set 4–20 Analog Low Input)
Range: 4.0 – 20.0 mA
Default: 4.0 mA
G213 (Set 4–20 Analog High Input)
Range: 4.0 – 20.0 mA
Default: 20 mA
G230–G232 (Set Maintenance Counters 1, 2, 3)
Range: 0.1 — 99.9 million cycles
Default: 0
G240 (Set Minimum Flow Setpoint)
Range: 0–280 cpm
Default: 0
G241 (Set Maximum Flow Setpoint)
Range: 0–280 cpm
Default: 280
G245 (Set Minimum Volume Setpoint)
Range: 0–9999 cycles
Default: 0
G246 (Set Maximum Volume Setpoint)
Range: 0–9999 cycles
Default: 9999
G247 (Batch Mode Target Flow)
Range: 1–280 cpm
Default: 10
G248 (Batch Start Interval)
Range: 0–99999
Default: 0
G300 (View Flow Rate)
Displays the pump flow rate.
G302 (View BUS Voltage)
Displays the BUS voltage in V.
G303 (View Motor Voltage)
Displays the RMS motor voltage in V.
G304 (View Motor Current)
Displays the RMS motor current in A.
G305 (View Motor Power)
Displays the motor power in W.
G306 (View Controller Temperature)
Displays the IGBT temperature in °C.
G307 (View Motor Temperature)
Displays the motor temperature in °C.
G308 (View Software Information)
Displays the software version and serial number.
G309 (View Leak Sensor Input)
0 = No leak detected
1 = Leak detected or leak sensor not installed
G310 (View Run/Stop Input)
0 = Stop
1 = Run
G311 (View 4–20 Analog Reading)
Displays the 4-20 mA analog input in mA.
G312 (Batch Interval Timer)
Range: 0–99999 seconds
G400 (Reset to Factory Defaults)
Resets all settings to factory defaults.