Graco Motor Control Operation (BLDC Models)
G204
ENABLE MAX POWER
MODE
Enable this setting to change the Over Current and Motor Temperature events
from Alarms to Deviations, which allows the pump to keep running with reduced
performance (may not maintain flow setpoint). The pump must be stopped to edit
this field.
0 = Disabled (Default)
1 = Enabled
G205
INPUT CURRENT LIMIT
Set the maximum input current allowed. The pump must be stopped to edit this
field.
0 = 12A (Default)
1 = 16A
G206
SET LEAK DETECTION
TYPE
Set the desired system response to a leak detection.
0 = Disabled or leak sensor not installed (Default)
1 = Deviation (system alerts the user but does not stop the pump)
2 = Alarm (system alerts the user and stops the pump).
G207
SET MAXIMUM
ACCELERATION
Set the time in seconds to maximum speed (280 cpm) from stop.
• Range is 1-300 seconds.
• Default is 20 seconds.
G208
SET MAXIMUM
DECELERATION
Set the time in seconds to stop from the maximum speed (280 cpm).
• Range is 1-300 seconds.
• Default is 1 second.
G209
CONFIGURE EXTERNAL
CONTROL
Configure the external control inputs. The pump must be stopped to edit this field.
0 = Disabled (Default)
1 = Stop Only (Manual Start)
2 = Start/Stop (Full Remote)
3 = Full Control (Both Start/Stop and Flow)
G210
SET or DISABLE
PASSWORD
Set the setup lockout password. Users who do not know the password will be able
to change information in the G100s (Maintenance) and G300s (Diagnostics), but
will be locked out from the G200s (Setup) and G400s (Advanced).
• Range is 1-99999.
• Enter 0 to disable the password.
• Enter 99999 to reveal the Advanced menu (menu G400).
• Default is 0.
G212
SET 4–20 ANALOG LOW
INPUT
Set the analog input level that corresponds to the minimum allowable control
setpoint (menus G240 or G245). This menu is visible only if external controls
(menu G209) are configured for full control (3).
• Range is 4.0 – 20.0 mA.
• Default is 4.0 mA.
G213
SET 4–20 ANALOG HIGH
INPUT
Set the analog input level that corresponds to the maximum allowable control
setpoint (menus G241 or G246). This menu is visible only if external controls
(menu G209) are configured for full control (3).
• Range is 4.0 – 20.0 mA.
• Default is 20 mA.
G230
SET MAINTENANCE
INTERVAL 1
Set the desired maintenance interval in millions of cycles.
• Range is 0.1 — 99.9 million cycles.
• Enter 0 to disable the maintenance counter.
• Default is 0.