Electrical Connections (BLDC Models)
Table 2 Connector 3 and 4 Specifications
Connector
Pin*
Function
Ratings
1 (Brown)
5VDCSupply
5 VDC, 20 mA Max
2 (White)
Digital Input (Spare)
Voltage Range: 5-24 VDC
Max Voltage: 30 VDC
Logic High: > 1.6 VDC
Logic Low: < 0.5 VDC
Internally Pulled-Up to 5VDC
3 (Blue)
Common
3 (Leak Sensor
and Spare
Input)
4 (Black)
Digital Input (Leak
Signal)
Voltage Range: 5-24 VDC
Max Voltage: 30 VDC
Logic High: > 1.6 VDC
Logic Low: < 0.5 VDC
Internally Pulled-Up to 5VDC
1 (Brown)
Common
2 (White)
Digital Input
(Start/Stop Signal)
Voltage Range: 12-24 VDC
Max Voltage: 30 VDC
Logic High: > 6.0 VDC
Logic Low: < 4.0 VDC
Internally Pulled-Up to 12 VDC
3 (Blue)
Common
4 (PLC Control)
4 (Black)
Analog Input (Flow
Signal)
Input Impedance: 250 Ohms
Current Range: 4-20 mA
Max Voltage: 12.5 VDC(continuous);
30 VDC(momentary)
Max Current: 50 mA
* Wire colors correspond to Graco cables.
Wiring Tips
• Use a grounded or shielded metal conduit for
power cabling.
• Use the shortest possible cables or wires for
incoming power.
• Use the shortest possible cables or wires between
the controller and the motor.
• Route low-voltage cables away from high-power
cables or wires or other known electromagnetic
interference EMI sources. If cables must cross,
cross at a 90° angle.
• The Graco Motor Control used with BLDC motors
has an integrated line filter, so no external filter is
necessary.
334188P
21
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910