Mount the Pump
To avoid serious injury or death from toxic fluid or
fumes:
• Never move or lift a pump under pressure. If
dropped, the fluid section may rupture. Always
follow the
Pressure Relief Procedure, page 29
,
before moving or lifting the pump.
NOTICE
The pump is heavy. To prevent damage from
dropping, always use 2 people or a lift to move the
pump. Do not use the manifolds to lift the pump.
Use at least one strap.
1. For all mountings, be sure the pump is secured
with screws through the mounting feet (D) and
through the mounting bracket on the gear box.
See
NOTICE
To prevent pump damage, use all eight
fasteners.
2. Make sure the surface is flat and that the pump
doesn’t wobble.
3. For BLDCmodels, securely mount the Graco
Motor Control using the provided mounting tabs.
4. For ease of operation and service, mount the
pump so fluid inlet and fluid outlet ports are easily
accessible.
5. Prolonged exposure to UV radiation will degrade
natural polypropylene components of the pumps.
To prevent potential injury or equipment damage,
do not expose pump or the plastic components
to direct sunlight for prolonged periods.
6. Cart Mounting: Some models can be ordered
mounted on a cart. For all other models, Cart
Mounting Kit 24Y543 is available.
Available Cart-Mounted Systems
System
Pump
Configuration Number
24Y388
648190
1050A-E,A05BA1SSCWCOPT
24Y552
648250
1050A-E,A06BA1SSCWCOPT
24Y553
648183
1050A-E,A05BA1SPSPSPPT
24Y554
648243
1050A-E,A06BA1SPSPSPPT
24Y555
648180
1050A-E,A05BA1TPACTP-
24Y556
648240
1050A-E,A06BA1TPACTP-
24Y557
648187
1050A-E,A05BA1BNBNBN-
24Y558
648247
1050A-E,A06BA1BNBNBN-
24Y559
650110
1050P-E,A05BP2PPPTPTSPT
24Y560
650154
1050P-E,A06BP2PPPTPTSPT
24Y561
651908
1050S-E,A05BS1SSPTPTSPT
24Y562
651944
1050S-E,A06BS1SSPTPTSPT
334188P
13
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910