Graco Motor Control Operation (BLDC Models)
G307
VIEW MOTOR
TEMPERATURE
Displays the motor temperature in °C.
• User cannot edit.
G308
VIEW SOFTWARE
VERSION & SERIAL
NUMBER
Displays the software configuration.
• User cannot edit.
• Information displayed includes software part number, software version, and
serial number.
G309
VIEW LEAK SENSOR
INPUT
Displays the leak sensor input status.
• User cannot edit.
• 0 = No Leak Detected
• 1 = Leak Detected, or leak sensor not installed
G310
VIEW RUN/STOP INPUT
Displays the run/stop input status.
• User cannot edit.
• 0 = Stop
• 1 = Run
G311
VIEW 4–20 ANALOG
READING
Displays the 4-20 mA analog input in mA.
• User cannot edit.
G312
BATCH INTERVAL TIMER
Displays the time (in seconds) remaining until the next batch will begin.
• User cannot edit.
G400
RESET TO FACTORY
DEFAULT
Resets all settings to factory defaults. This menu appears only if the password is
set to 99999 on menu G210. When “RESET” appears on the display, press and
hold
for 2 seconds to reset the system.