Graco Motor Control Operation (BLDC Models)
Table 5 Available Menus with Descriptions
Setup Mode
G100
VIEW EVENTS
Displays the last 20 system event codes. Use
and
to scroll though the
event codes
G101
VIEW or RESET BATCH
VOLUME
Displays the batch volume that has been dispensed. This value is in the Flow
Units selected in menu G201. Changing G201 will cause the value in G101 to
change to the new flow unit.
• Hold
for 2 seconds to reset the counter.
• Units are user selectable. See Set Flow Units (menu G201).
G102
VIEW LIFE TOTAL
Displays the total number of pump cycles for the life of the pump.
• Displays in cycles (XXXXX), thousands of cycles (XXXXK), or millions of cycles
(XXXXM).
G130
VIEW MAINTENANCE
COUNTER 1
Displays the number of pump cycles since the last maintenance.
• Hold
for 2 seconds to reset the counter.
• Displays in cycles (XXXXX), thousands of cycles (XXXXK), or millions of cycles
(XXXXM).
G131
VIEW MAINTENANCE
COUNTER 2
Displays the number of pump cycles since the last maintenance.
• Hold
for 2 seconds to reset the counter.
• Displays in cycles (XXXXX), thousands of cycles (XXXXK), or millions of cycles
(XXXXM).
G132
VIEW MAINTENANCE
COUNTER 3
Displays the number of pump cycles since the last maintenance.
• Hold
for 2 seconds to reset the counter.
• Displays in cycles (XXXXX), thousands of cycles (XXXXK), or millions of cycles
(XXXXM).
G200
SET CONTROL MODE
Set the pump control mode. The pump must be stopped to edit this field.
0 = Flow Control (default)
1 = Batch C ontrol
G201
SET FLOW UNITS
Set the display flow units, which also sets the internal volume units.
0 = cycles per minute (cpm, default)
1 = gallons per minute (gpm)
2 = liters per minute (lpm)
G203
SET PUMP K-FACTOR
Set the pump displacement per cycle. Follow the
Flow Calibration Procedure, page 28
, or the
Batch Calibration Procedure, page 29
,
to obtain the information needed for this menu. Units are always cc/cycle. The
menu is visible only if flow units (menu G201) are set to gpm (1) or lpm (2), not
cpm (0). The pump must be stopped to edit this field.
• Range is 52–785 cc/cycle (Default 523).