Appendix A - Modbus Variable Map
Modbus
Modbus
Modbus
Register
Register
Register
Variable
Variable
Variable
Register
Register
Register
Access
Access
Access
Size
Size
Size
Notes/Units
Notes/Units
Notes/Units
Intelligent Paint Kitchen Registers
Run
406100
Secs Counter
Read Only
0 - 60
406101
Pump Status Bits
Read Only
bit 0 = Pump trying to move
bit 1 = Pump actually moving
bit 2 = Active Alarm
bit 3 = Active Deviation
bit 4 = Active Advisory
bit 5 = Setup Modified
(Registers 6141-6159)
bit 6 = Reserved/unused
bit 7 = Run Status
bit 8 = Profile 1 Modified
bit 9 = Profile 2 Modified
bit 10 = Profile 3 Modified
bit 11 = Profile 4 Modified
406102
Actual Pump Speed
Read Only
0 - 65535
406103
Actual Pump Flow Rate
Read Only
406104
Estimated Pump Force or Pressure
Read Only
406105
Transducer 1 Pressure
Read Only
0 - 65535
406106
Transducer 2 Pressure
Read Only
0 - 65535
406107
ADCM Input Status Bits
Read Only
bit 0 / bit 1:
0 = Stop
1 = Run
2 = Toggle
bit 2 = Agitator Halt Status
406108
ADCM Output Bits
Read / Write
0 = Fill Pump
1 = Aux Output
406109
Active Profile Number
Read / Write
0 - 4
406110
Agitator VFD/Analog Output #2 %
(4 - 20 ma)
Read / Write
0 - 100
406111
VFD Enable Status
Read / Write
0 = Off
1 = On
406112
Actual Tank Level #1 Pct
Read / Write
0 - 100
406113
Agitator Profile Enable
Read / Write
0 = Disabled
1 = Enabled
406114
Batch Total High Word
Read Only
0 - 65535
406115
Batch Total Low Word
Read Only
0 - 65535
406116
Grand Total High Word Pump 1
Read Only
0 - 65535
406117
Grand Total Low Word Pump 1
Read Only
0 - 65535
406118
Grand Total High Word Pump 2 (x2)
Read Only
0 - 65535
406119
Grand Total Low Word Pump 2 (x2)
Read Only
0 - 65535
3A2527H