Appendix A - Modbus Variable Map
Appendix
Appendix
Appendix A
A
A --- Modbus
Modbus
Modbus Variable
Variable
Variable Map
Map
Map
To communicate through fiber optics with the E-Flo
DC Control Module, reference the appropriate
hardware as shown in manual 332356. That
manual indicates various options for connecting
fiber optic cables from the control module to the
non-hazardous area. The following table lists
Modbus registers available to a PC or PLC located in
the non-hazardous area.
Table 4 shows the registers needed for basic
operation, monitoring, and alarm control features.
Tables 5 and 6 provide bit definitions as needed for
certain registers. Table 7 shows the units and how to
convert the register value to a unit value.
Reference the Modbus communication settings
selected in
.
Table
Table
Table 4
4
4 Modbus
Modbus
Modbus Registers
Registers
Registers
Modbus
Modbus
Modbus
Register
Register
Register
Variable
Variable
Variable
Register
Register
Register
Access
Access
Access
Size
Size
Size
Notes/Units
Notes/Units
Notes/Units
403225
Fill Pump Solenoid Out
Read/Write
16 Bit
0 = Off, 1 = On
403226
Solenoid Out Keep Alive
Read/Write
16 Bit
Write any value to activate.
403227
Reed Switch Count
Read/Write
16 Bit
Cycle count
403228
Tank Level 1 Full Pressure
Read/Write
16 Bit
Pressure units, see Table 7.
403229
Tank Level 2 Full Pressure
Read/Write
16 Bit
Pressure units, see Table 7.
403230
Actual Tank Level 1%
Read/Write
16 Bit
Pressure units, see Table 7.
403231
Actual Tank Level 2%
Read/Write
16 Bit
Pressure units, see Table 7.
403232
Configurable IO Type
Read/Write
16 Bit
0 = Reed switch input,
1 = Drum cover switch input
403233
Agitator Half Status
Read/Write
16 Bit
0 = Drum cover down,
1 = Drum cover up,
2 = Accessory solenoid out
403234
Accessory Solenoid Out
Read/Write
16 Bit
0 = Off, 1 = On
404100
Pump Status Bits
Read Only
16 Bit
See Table 6 for bit definitions.
404101
Actual Pump Speed
Read Only
16 Bit
Speed units, see Table 7.
404102
Actual Pump Flow Rate
Read Only
16 Bit
Flow units, see Table 7.
404103
Actual Pump Pressure
Read Only
16 Bit
Percent pressure, see Table 7.
404104
Transducer 1 Pressure
Read Only
16 Bit
Pressure units, see Table 7.
404105
Transducer 2 Pressure
Read Only
16 Bit
Pressure units, see Table 7.
404106
Batch Total High Word
Read Only
16 Bit
Volume units, see Table 7.
404107
Batch Total Low Word
Read Only
16 Bit
Volume units, see Table 7.
404108
Grand Total High Word
Read Only
16 Bit
Pump cycles, see Table 7.
404109
Grand Total Low Word
Read Only
16 Bit
Pump cycles, see Table 7.
404110
Maintenance Total High Word
Read Only
16 Bit
Pump cycles, see Table 7.
404111
Maintenance Total Low Word
Read Only
16 Bit
Pump cycles, see Table 7.
404112
Pump Alarms 1 High Word
Read Only
16 Bit
See Table 5 for bit definitions.
404113
Pump Alarms 1 Low Word
Read Only
16 Bit
See Table 5 for bit definitions.
404114
Display Alarms High Word
Read Only
16 Bit
See Table 5 for bit definitions.
30
3A2527H