Appendix B - Pump Control from a PLC
4.
View
View
View pump
pump
pump status:
status:
status: Read register 404100 to see
the status of the pump. See Appendix A, Table
6, for a description of each bit.
• Example 1: Register 404100, bit 1, reads 1 if
the pump is currently moving.
• Example 2: Register 404100, bit 2 reads 1 if
the pump has an active alarm.
5.
Monitor
Monitor
Monitor alarms
alarms
alarms and
and
and deviations:
deviations:
deviations: Read register
404112 to 404115. Each bit in these registers
corresponds to an alarm or deviation. See
Appendix A, Table 5. I
• Example 1: Pressure falls below the minimum
setting entered on Setup Screen 2. It will show
on bit 4 of register 404113 if minimum pressure
is set to Alarm, and on bit 5 of register 404113
if minimum pressure is set to Deviation.
• Example 2: The system is set up for a
pressure transducer on Setup Screen 8, but no
transducer is detected. It will show on bit 1 of
register 404114.
6.
Monitor
Monitor
Monitor pump
pump
pump cycle
cycle
cycle rate,
rate,
rate, flow
flow
flow rate,
rate,
rate, and
and
and pressure:
pressure:
pressure:
Read registers 404101 to 404105. Note that
pressure is available only if a pressure transducer
is connected to the display. Register 404104
shows the pressure on transducer 1. Register
404105 shows the pressure on transducer 2. See
Appendix A, Table 7 for units for these registers.
• Example 1: If register 404101 reads 75, the
pump speed is 7.5 cycles/minute.
• Example 2: If register 404103 reads 67, the
pump is operating at 67 percent pressure.
7.
Reset
Reset
Reset active
active
active alarms
alarms
alarms and
and
and deviations:
deviations:
deviations: Clear the
condition that caused the alarm. Set register
404202, bit 0, to 1 to clear the alarm. The pump
will be in profile 0 due to the alarm. Set 404201
to the profile to run the pump again.
42
3A2527H