This guide shows how to use the information in Appendix A to control a pump remotely from a PLC. The steps
progress from basic pump control to more advanced monitoring and alarm control features.
It is important that you first follow all directions in the
Setup Screens to configure your system properly.
Test that the pump operates correctly when controlled
from the Display. Make sure the display, fiber optics,
communication gateway, and PLC are connected
properly. Refer to Communication KIt manual. Use
Setup Screen 12 to enable remote control and set
your modbus preferences.
1.
Enable
Enable
Enable PLC
PLC
PLC control:
control:
control: Set register 404200 to 1.
2.
Run
Run
Run a
a
a pump:
pump:
pump: Set register 404201. Enter 0 for
stopped, 1 to 4 for the profile.
3.
View
View
View pump
pump
pump profile:
profile:
profile: Read register 404201. This
register updates automatically to reflect the
actual pump status. If the profile is changed from
the display, this register changes as well. If the
pump stops due to an alarm, this register will
read 0.