Maintenance
28
3A6941B
25. Loosen and remove the extension tube (26) from
the top housing. Remove two backup rings (14) and
the o-ring (15) (F
. 40).
26. Pull out the pump rod (F
. 41).
27. Remove the retaining nut (9) located on the upper
housing (F
28. Remove the outer o-ring (28) from the retaining nut
. 43).
29. Remove the throat screw (29) to get to the inner
o-ring (30) (F
. 43).
30. Remove the bronze washer (31) from the pump
housing (F
31. Remove the throat seal (32) (u-cup) (F
F
IG
. 40
F
IG
. 41
26
14
15
27
F
IG
. 42
F
IG
. 43
9
28
30
29
31
32