Installation
6
3A6941B
Installation
Grounding
To ground the pump: remove the ground screw (Z)
located on the back of the gear box and insert it through
the eye of the ring terminal (W) at end of ground wire
(Y). Fasten the ground screw (Z) back onto the pump
and tighten securely. Connect the other end of the
ground wire (Y) to a true earth ground (F
. 1). To order
a ground and wire clamp, order Part 222011.
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
To relieve pressure in the system, use two wrenches
working in opposite directions on the pump outlet fitting
to slowly loosen the fitting only until no more lubricant or
air is leaking from the fitting (F
. 2).
The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
F
IG
. 1
Z
W
Y
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.
F
IG
. 2
Summary of Contents for Compact Dyna-Star
Page 11: ...Installation 3A6941B 11 Typical Wiring Series Parallel Systems FIG 6...
Page 29: ...Maintenance 3A6941B 29 32 Remove the check valve and o ring 37 FIG 44 FIG 44 37...
Page 42: ...Parts 42 3A6941B 43 42 41 52 55 56 57 54 47 48 49 50 51 53...
Page 48: ...Mounting Dimensions Stand Alone Pump 48 3A6941B Mounting Dimensions Stand Alone Pump...
Page 49: ...Notes 3A6941B 49 Notes...