Setup
16
3A6941B
The auto-fill shut off (V) is used to refill the grease tank
(K) in an automatic lubrication system. When the grease
level in the tank is full, the auto-fill shut off automatically
ends the filling operation.
Always fill the tank (K) to full during refilling.
As grease is added to the tank (K), the follower plate (Y)
is pushed to the top of the tank (K) and pushes up the
valve pin (V1) which closes the inlet fluid path. Pin (V2)
pops up when the tank is full (F
. 12).
When the fluid refilling path closes, the refilling line (GG)
pressurizes and brings the remote fill station pump (AA)
to a pressurized stall condition.
Note: The operator must monitor the system during fill-
ing of the tank to prevent any accidental fluid overflow.
Refill the Tank: Pumps with an Auto-fill
Shut Off (AFSO)
1.
Pull and hold the fill valve pressure relief knob (FF)
long enough to relieve line pressure between the fill
valve (EE) and the auto-fill shut off valve (V).
2.
Verify the auto-fill shut off pin (V2) is down, indicat-
ing it is reset (F
. 13).
3.
Remove the dust cover (DC) from the fill coupler
(FC) on the fill valve (EE) (F
F
IG
. 12
The breather (J) vents the tank to the atmosphere. If it
is plugged the tank will over-pressurize and rupture.
Be sure the breather is not plugged before filling the
pump.
V2
F
IG
. 13
F
IG
. 14
V2
Pin Down
EE
DC
FC
FF
Summary of Contents for Compact Dyna-Star
Page 11: ...Installation 3A6941B 11 Typical Wiring Series Parallel Systems FIG 6...
Page 29: ...Maintenance 3A6941B 29 32 Remove the check valve and o ring 37 FIG 44 FIG 44 37...
Page 42: ...Parts 42 3A6941B 43 42 41 52 55 56 57 54 47 48 49 50 51 53...
Page 48: ...Mounting Dimensions Stand Alone Pump 48 3A6941B Mounting Dimensions Stand Alone Pump...
Page 49: ...Notes 3A6941B 49 Notes...