Setup
3A6941B
19
1.
Connect the lubricant supply hose (JJ) from the
remote filling station pump (AA) to the fill port (G)
(F
2.
Slowly turn on the supply lubricant until the level of
lubricant reaches the overflow port (H). When the
tank (K) is full (or overfilled) grease will flow out of
the overflow port. (H).
Note: For pump tanks (K) with a follower plate (Y),
fill the tank until the follower plate reaches the
overflow port (H) and grease flows out.
F
IG
. 17
The breather (J) vents the tank to the atmosphere. If it
is plugged the tank will over-pressurize and rupture.
Be sure the breather is not plugged before filling the
pump.
NOTICE
To prevent damage to the unit:
•
Check breather (J) vent for proper operation
before filling the tank (K).
•
Do not fill tank (K) beyond the overflow port (H).
•
Do not use the breather (J) as a port to fill the tank.