Setup
3A6941B
17
4.
Connect the supply hose (JJ) between the remote
fill station pump (AA) and fill coupler (FC) port
marked with an “I” (F
. 14).
5.
Start the remote fill station pump (AA).
6.
When the tank (K) is filled:
•
The remote fill station pump (AA) stalls
(dead-heads),
•
the auto-fill shut off pin (v2) pops up as shown in
F
. 15,
•
The pressure gauge needle rises to the fill
pump’s set pressure.
Note: If the pump does not stall (dead-head) there is a
leak in the system.
NO
7.
Turn off the remote fill station pump (AA).
8.
Pull and hold the fill valve pressure relief knob (FF)
long enough to relieve line pressure between fill
valve (EE) and Auto-fill Shut Off Valve (V) and
between remote fill station pump (AA) and fill valve
(EE).
Note:
The length of time it takes to vent the pressure
varies depending on the system design and installation.
In some installations it may be necessary to repeat Step
8 to ensure pressure is relieved.
9.
Disconnect the supply hose (JJ) from the fill coupler
(FC) (F
10. Replace the dust cover (DC) over the fill coupler
(FC).
NOTICE
To prevent damage to the unit:
•
Check breather (J) vent for proper operation
before filling the tank (K).
•
Do not fill tank (K) beyond the overflow port (H).
•
Do not use the breather (J) as a port to fill the tank.
F
IG
. 15
V2
Summary of Contents for Compact Dyna-Star
Page 11: ...Installation 3A6941B 11 Typical Wiring Series Parallel Systems FIG 6...
Page 29: ...Maintenance 3A6941B 29 32 Remove the check valve and o ring 37 FIG 44 FIG 44 37...
Page 42: ...Parts 42 3A6941B 43 42 41 52 55 56 57 54 47 48 49 50 51 53...
Page 48: ...Mounting Dimensions Stand Alone Pump 48 3A6941B Mounting Dimensions Stand Alone Pump...
Page 49: ...Notes 3A6941B 49 Notes...