Maintenance
30
3A6941B
Reassemble
1.
Place throat seal (32) (u-cup) into the pump
housing, lips downward (F
2.
Place the bronze washer (31) on top of the throat
seal (32) (u-cup) (F
3.
Replace the inner o-ring (30) from the retaining nut
(9) with a new o-ring and grease lightly. (F
4.
Replace the outer o-ring (28) from the retaining nut
(9) with a new o-ring and grease lightly (F
5.
Place the throat screw (29) into the retaining nut (9)
using an Allen wrench and tighten (torque 16 ft-lb/
21.7 N•m)
6.
Grease the o-ring (28) and place the retaining nut
(9) into the pump housing and tighten slightly (F
F
IG
. 45
F
IG
. 46
32
31
30
28
F
IG
. 47
F
IG
. 48
29
9
9
28