Maintenance
36
3A6941B
33. Place the o-ring onto the check valve, and then
place into the pump outlet and tighten (torque 16
ft-lb/21.7 N•m) (F
. 68).
There is air located between the pump tube and the
tube-in-tube. Remove this air by filling it with grease to
prime the pump. If this is not done, the pump may lose
priming during operation.
34. Connect the refill pump to the fill coupler (F
F
IG
. 68
37
F
IG
. 69
Fill Coupler
Refill Pump
Refill Pump
Refill Filter
Fill Coupler
Pump
Tube-in-tube
Pump Tube