Maintenance
24
3A6941B
Maintenance
Disassemble
1.
Relieve pressure, following the
, page 6.
2.
Disconnect the power to the system.
3.
Loosen and remove the four bolts (3) holding the
motor (1) to the pump, then remove the motor (1)
and the o-ring (2) (F
4.
Loosen and remove the four bolts and four washers
holding the pump to the tank (41) with a 5 mm Allen
wrench (F
. 25).
5.
Pull the pump out of the tank (41).
6.
Remove the pressure relief valve cartridge (5) (F
7.
Remove the two bolts (6) and two nuts (not shown)
from the protection cover (8) (F
8.
Remove the protection cover (8).
F
IG
. 24
F
IG
. 25
1
2
3
41
47
48
F
IG
. 26
F
IG
. 27
5
8
6
Summary of Contents for Compact Dyna-Star
Page 11: ...Installation 3A6941B 11 Typical Wiring Series Parallel Systems FIG 6...
Page 29: ...Maintenance 3A6941B 29 32 Remove the check valve and o ring 37 FIG 44 FIG 44 37...
Page 42: ...Parts 42 3A6941B 43 42 41 52 55 56 57 54 47 48 49 50 51 53...
Page 48: ...Mounting Dimensions Stand Alone Pump 48 3A6941B Mounting Dimensions Stand Alone Pump...
Page 49: ...Notes 3A6941B 49 Notes...