Software
English, Revision 06, Date: 14.12.2016
30
-
C(
)N-Parameter (section 5.2.2.5 on page 35)
-
P(
)ofibus parameter (section 5.2.2.6 on page 36)
-
(
)rite Transponder (section 5.2.2.9 on page 37)
-
CS(
)-Out (section 5.2.2.6 on page 36)
-
(
)pdate firmware (section 5.2.2.9 on page 37)
-
(
)uit monitor: by pressing Q the monitor programm is left, if serial procedures
3964R
or
transparent
are active. When procedure
Monitor only
is active
the monitor program cannot be left
5.2.2.2
(T)ime & Code
This menu enables the setting of timing values for the transponder decoding, the po-
sition calculation and the positioning pulse. The first three values are determined by
the selected code transfer proceeding and
cannot be altered
:
Figure 15
Menu: (T)ime & Code
By pushing
one of the two receive channels can be chosen. Normally it is set to
sum channel S. In order to reduce interferences, it is possible to switch to the differ-
ence channel.
NOTE!
If the difference channel is used a code will be left out in the mid-
dle (at zero)!
Since the code transfer of trovan™ transponders is only secured by a simple parity
check, two additional safety strategies have been implemented in order to achieve a
higher data protection:
S:0008 X:+0006 Code: 00000000 Read: 0:
Frx[/Hz]:66800 Ftx[/Hz]:127980
U[/mV]:22400 I[/mA]: 290 T[Grd.C]:+24 E: 0000 N: 0
(S)elect Code Channel S
(H)igh-Nibble of RW-Code [0..F,>F]: 10
(N)umber of equal Codes [0..15]: 1
(L)evel for Positioning [10.1023]: 256
PosiPulse (a)fter Decoding 1
(T)hreshold Decoding [10.1023]: 256
(1) switch Reference Transponder: 0
(P)osi-Pulse Time [n*1ms]: 100
(O)ne Positioning Pulse per Crossing 0
(X) Timed Positioning Pulse 1
(Q)uit Menue