4.2.4.3.2
CAN Message Object 1 (transmission object, compatible to former
firmware versions)
4.2.4.3.3
CAN Message Object 2 (A identifier; transm. object)
4.2.4.3.4
CAN Message Object 3 (B identifier, transm. object)
To interpret these values refer also to Table 5 on page 17. This object serves the sur-
veillances of the parameters.
Byte #
Length
Type
Meaning
1,2
2 Byte
unsigned int
System status according to Table 6
on page 18
3,4,5,6
4 Byte
unsigned long
32 bit transponder code
7
1 Byte
unsigned char
Number of code readings of the last
transponder crossing
Table 8
Structure of the CAN message object 1
Byte #
Length
Type
Meaning
1,2
2 Byte
unsigned int
System status according to Table 6 on
page 18
3,4,5,6
4 Byte
unsigned long
32 Bit transponder code
7,8
2 Byte
signed int
Dummy entry
Table 9
Structure of CAN message object 2
Byte #
Length
Type
Meaning
1,2
2 Byte
unsigned int
sum voltage
3,4
2 Byte
signed int
difference voltage
5
1 Byte
unsigned char
number of code readings the last trans-
ponder crossing
6
1 Byte
unsigned char
operating voltage
7
1 Byte
unsigned char
operating current
8
1 Byte
signed char
temperature
Table 10
Structure of CAN Message Object 3