![Gotting HG G-98760-C Series Device Description Download Page 16](http://html1.mh-extra.com/html/gotting/hg-g-98760-c-series/hg-g-98760-c-series_device-description_2247540016.webp)
Components and Operation
English, Revision 06, Date: 14.12.2016
16
The digital positioning output indicates the crossing of the center line of the antenna
in direction of travel (X- direction). Its duration is adjustable within a millisecond pat-
tern. In addition it can be limited to one pulse per crossing.
Both connecters for positioning are not internally connected with +24V or GND as in
some systems a strict isolation of potentials has to be kept. Due to security require-
ments the current in these outputs is limited to 20mA. If e.g. a 24 V output is needed,
contact number 9 has to be connected with +24V and contact number 10 has to be
connected with GND using a resistor of 1 KOhm.
Figure 11
Connection possibilities positioning pulse
4.2.3
Switch-on characteristics
Once the supply voltage has been applied, the antenna requires 10 s until it reacts to
data input, or outputs data protocols. During these 10 s, a software download may be
started (also refer to section 5.2.2.4 on page 33). A further 16 seconds are necessary,
in case the automatic transmitter tuning function is activated
5
Rx (RS232)
+ RX (RS422)
6
not connected
- RX (RS422)
7
Tx (RS232)
+ TX (RS422)
8
not connected
- TX (RS422)
9
+ Posi Pulse (see below)
10
- Posi Pulse (see below)
11
not connected
12
signal ground
casing
shielding
Contact
HG 98769YC
HG 98760XC
Table 4
Allocation for 12-pin plug X3 for suppliance of the antenna (see Figure 10
on page 14), Profibus version (Section 2 of 2)
Pin
HG G-98760
1
9
10
2
Posi
Pulse
+Posi
-Posi
+24 VDC
GND
Connecting to a relay
Connecting to a PLC
Pin
HG G-98760
1
9
10
2
Posi
Pulse
+Posi
-Posi
+24 VDC
GND
PLC