Device Description HG G-71912-A | English, Revision 03 | Date: 28.03.2018
33
Software – Chapter 6
6.2.2.1 Main Menu
Figure 13
Main menu of the monitor program
Each of the screen menus contains important system variables in the first line (refer also to
Table 36), as they also appear in the output telegram (described in section 5.3.2.1.1 on page
18). The last line on the screen contains possible status messages, if e.g. predetermined val-
ue ranges have not been observed during input.
Other menus are activated by pressing the characters in (brackets). Before altered values are
transferred into the permanent memory, the pass word
815
has to be entered by pressing
. This prevents unintended alterations of values. With
the values are saved after alter-
ation and input of the password.
The access to the service menu which can be called with
. It is protected by a specific
password. No preferences in this menu are relevant for user.
By typing
, the system status can be explained in clear text. By pushing
the menu can
be left.
Description of the system variables
S
Measured voltage of the sum coil within the cover of the casing in sam-
ples (max. 1023).
D
Measured voltage of the difference coil within the cover of the casing in
samples (max. ±1023).
Code
The 32 information bits of the transpondercode in hexadecimal notation.
Read
Number of readings per transponder crossing. This value is preserved until
another transponder is detected. It is also deleted through Noise.
E
State of system in hexadecimal notation. The meaning of each bit is
explained in Table 7 on page 19.
N
Number of reading errors per transponder crossing. This value is stored
until a new transponder has been detected.
Table 36
Description of the system variables (monitor program)
S:0022 D:+0025 Code: 000fffff Read: 114 E: 0120 N: 0 Ftx[Hz]:128000
(W)rite Transponder
(S)erial Output
P(a)rallel Interface
(C)AN-Parameters
P(o)sitioning Pulse
D(e)coding
CS(V) 38,4KB:Code,Sum,Dif,Tr,Co,Po,Rd,Cnt<crlf>
S(y)stemstatus
(P)assword
(L)oad Values to EEProm
Se(r)vice
Se(t)up Ref.transponder Values <S:969 D:-560>
(U)pdate Firmware
(Q)uit Monitor
Software Version 71914A71.08 / 15.APR.2009 Serial Number: 9999999