Device Description HG G-71912-A | English, Revision 03 | Date: 28.03.2018
46
Chapter 8 – Technical Data
8
Technical Data
Interpreter HG G 71912-A
Dimensions
Dimensions see Figure 3 on page 9
EMC
Length of cable
The connection cable should not be longer than 3 m!
Alimentation
24 V ±10 %, < 500 mA
Operating temprature
0 to +50
o
C
Mechanical stability
5 g 11 ms / 2 g 10 to 55 Hz
Protection class
IP 65
Connection
see different variants in Table 1 on page 6
Duration of programmation
approx. 300 ms
Serial interface
RS 232 with 9600 or 19200 Baud, even parity, 1 stop
bit, procedure 3964R or transparent
Crossing impulse
24 V, 20 mA
CAN bus (version HG 71912ZA/
XA)
non-potentially isolated CANopen
®
,
Device Profil DS 401, Node ID and transmission rate are
configurable via a serial interface/SDO. A terminator
can be activated by a Ein Abschlusswiderstand kann
über eine jumper.
Parallel output (version
HG 71912YA)
Data output: 15 bit, DTR, 24V, no limitation of current!
Table 38
Technical Data Interpreter HG G 71912-A
Electromagnectic compability (EMC)
Checking of
In accordance with European Testing
Standard
Emitted interference
Noise radiation
EN 55 022 Klasse A
Stability
Casing
Electromagnetic HF field, amplitude-
modulated
EN 61000-4-3
Discharge of statical electricity
EN 61000-4-2
Signal tap
High frequency asymmetric
EN 61000-4-6
fast transients
EN 61000-4-4
Table 39
EMC checking