Device Description HG G-71912-A | English, Revision 03 | Date: 28.03.2018
14
Chapter 4 – Commissioning
Figure 9
Diagram: commissioning protocol / disturbed decoding (but still functional)
In the following diagram it is shown how a false set
Threshold for Decoding
or
Threshold for
Positioning
can cause erroneous
POSI pulses
.
Figure 10
Diagram: commissioning protocol/POSI-Pulse triggered by noise & too high Thresh.
In this example the thresholds are set to 100 samples. The bit
TRANS_IN_FIELD
is set con-
stantly. After a successful decoding a correct
POSI pulse
is triggered. As the software does
not know, that the antenna field is left then, each further zero crossing of the difference sum
generates a new
POSI pulse
.
Disturbed decoding (function still available)
POSI-Pulse triggered by noise & too high threshold