106
MDE-LEDI-NETWORK-IN-4065V1.0
1. PROCEDURE TO fOLLOW TO CHaNGE THE BaTTERY
Tools : Screw Driver
►
Gorgy Timing reference : BaT1728S
►
Life period : 5 years
►
BaTTERY CHECKING
Connect the product to the 230VAC during one hour.
►
Remove the power supply.
►
Open the product with the screw driver, the battery is located between the power
►
supply card and the display card
Disconnect the old battery with the screw driver.
►
Check the voltage, if the voltage is
►
less than 7V, the battery is on failure
.
Connect the new battery with the screw driver.
►
aPPENDIx
D – MaINTENaNCE
Display
Output 1
Output 2
Output N
Battery
Synch. input
…
Power
Supply