100
MDE-LEDI-NETWORK-IN-4065V1.0
This appendix contains a description of the time code used for the different kind of
outputs.
1. ‘A’ AND ‘R’ TYPE CARDS (ASCII+TOP OUTPUT)
The default configuration is shown below:
The PPS is generated every 30 seconds and is 1 second long;
►
The ASCII frame is generated at the same time than the PPS. This frame is a 23
►
characters frame with following format:
STX
D A
Y
D D / M M /
Y Y
H H
: M M :
S S
CR
Here is a description of the different fields of this frame:
Field Size
Value/Meaning
STX
1
A single byte which value is 2 – mark the beginning of the frame.
DAY
3
The day in the week in a human-readable way (MON for Monday, TUE
for Tuesday, WED for Wednesday, THU for Thursday, FRI for Friday,
SAT for Saturday, SUN for Sunday)
DD
2
Day in the month on two characters ASCII (01-31)
MM
2
Month in the year on two characters ASCII (01-12)
YY
2
Year on two characters ASCII (00 for 2000 – 99 for 2099)
HH
2
Hours on two characters ASCII (00 to 23)
MM
2
Minutes on two characters ASCII (00 to 59)
SS
2
econds on two characters ASCII (00 to 59)
CR
1
A single byte which value is 13decimal – mark the end of the frame
aPPENDIx
B – OUTPUT CODE fORMaT
aPPENDIx
B – OUTPUT CODE fORMaT
Summary of Contents for LEDI Network IN
Page 1: ...MDE LEDI NETWORK IN 4065V1 0 LEDI NETWORK in MODE D EMPLOI page 3 USER GUIDE page 49...
Page 40: ...40 MDE LEDI NETWORK IN 4065V1 0 2 Carte type B AFNOR IRIG B NFS87500 2 1 Format de la trame...
Page 47: ...47 MDE LEDI NETWORK IN 4065V1 0 NOTES FRANCAIS...
Page 49: ...49 MDE LEDI NETWORK IN 4065V1 0 USER GUIDE LEDI Network in ENGLISH...
Page 115: ...115 MDE LEDI NETWORK IN 4065V1 0 NOTES ENGLISH...