46

MDE-LEDI-NETWORK-IN-4065V1.0

NOTES

Configuration des appareils

Description de l’installation

Date d’installation

Nom de l’installateur

Appareil

Sortie

Fuseau horaire et politique 

 

de changement d’heure

aNNExE 

E – DOCUMENTS COMPLéMENTaIRES

Summary of Contents for LEDI Network IN

Page 1: ...MDE LEDI NETWORK IN 4065V1 0 LEDI NETWORK in MODE D EMPLOI page 3 USER GUIDE page 49...

Page 2: ...de vous d barrasser de cet quipement dans un site de collecte pr vu cet effet s par ment des ordures m nag res Pour de plus amples informations contactez votre revendeur votre site de collecte ou les...

Page 3: ...Int gration dans votre r seau 13 2 2 Configuration des cartes de sortie 14 2 2 1 Introduction 14 2 2 2 Configuration par d faut 14 2 2 3 Changer les r glages 14 2 2 4 Param tres g n riques 15 A Fusea...

Page 4: ...e pour carte type A ASCII TOP 37 Annexe B Format du code de sortie 39 1 Carte Type A sortie ASCII TOP 39 2 Carte type B AFNOR IRIG B NFS87500 40 2 1 Format de la trame 40 2 2 Encodage des bits 41 Anne...

Page 5: ...n utilisant le LEDI Network IN avec un serveur Gorgy Timing vous facilitez fortement l installation et l utilisation Allez directement la section 1 1 pour l installation rapide 1 1 Installation rapide...

Page 6: ...g vous recommande d inscrire pour chaque produit son empla cement physique Ceci est possible gr ce au logiciel GTNetMng fournit sur le CDROM Pour plus d informations voir la partie 31 2 1 2 Configurez...

Page 7: ...ortie Chaque carte peut tre configur e pour fournir plusieurs heures locales Cette configu ration est effectu e au travers d un navigateur WEB voir la partie 32 1 3 G n ralit s Cette partie d crit les...

Page 8: ...de la d rive 3 Le sch ma suivant montre l volution des deux horloges avec et sans d calage L objectif de la synchronisation d un client NTP sur un serveur NTP est de r duire autant que possible le d c...

Page 9: ...ction de la charge du r seau ou de la charge du serveur NTP Plus grave le temps de transmission du client au serveur n est g n ralement pas le m me que du serveur au client En r alit sur une grande p...

Page 10: ...r seau Jusqu 3 minutes sont n cessaires pour terminer cette tape Travail Fonctionnement normal le client NTP value en permanence son d calage et sa d rive par rapport au serveur Commutation Comme tro...

Page 11: ...aucun serveur DHCP n est install le LEDI Network IN utilise automatiquement une adresse IP par d faut de type 169 254 x y avec x et y compris entre 0 et 255 L identificateur DHCP par d faut du produi...

Page 12: ...la ligne du produit que vous souhaitez configurer La fen tre suivante s affiche Entrez les param tres r seau et la localisation physique et cliquez sur le bouton Set Nom num ro de s rie et localisatio...

Page 13: ...votre LEDI Network IN il vous suffit de taper inrack3 dans le champs d adresse de votre navigateur WEB Si vous avez plusieurs produits connect s votre installation il est fortement recom mand de suivr...

Page 14: ...res 2 2 2 Configuration par d faut Quand vous recevez ce produit Gorgy Timing toutes les cartes de sortie sont configu r es pour fournir l heure UTC et le temps est constant toute l ann e pas de chang...

Page 15: ...utilisez l interface WEB et r glez le d calage GMT 1 00 B Politique de changement d heure DST Day Saving Time En plus du fuseau horaire beaucoup de pays appliquent leur politique de change ment d heur...

Page 16: ...3 1 Conditions au d marrage Au d marrage l heure et la date du LEDI Network IN ne sont pas valides et ne sont dons pas affich s Ainsi vous voyez les messages suivant Quand l appareil d marre tous les...

Page 17: ...2 Affichage de l heure Quand aucune alarme n est activ e et que le LEDI Network IN est correctement synchro nis sur un serveur l heure actuelle du serveur est affich e en permanence L cran affiche al...

Page 18: ...r indique alternativement l heure comme d crit dans la partie pr c dente et les informations suivantes 3 5 Conditions d alarmes majeures Il existe deux alarmes diff rentes Si la LEDI Network IN ne peu...

Page 19: ...teur WEB comme ci dessous et appuyez sur Entr e 6 Le chargement de l applet JAVA prend environ 20 secondes Si le chargement choue il peut y avoir plusieurs raison cela 1 l adresse IP n est pas valide...

Page 20: ...NTP diagnostic et configuration du comportement du logiciel NTP 4 Output diagnostic et configuration des cartes de sortie et de l afficheur Le bouton Set Up rafraichit instantan ment la configuration...

Page 21: ...uit Param tres r seau Voici les diff rents param tres IP mode Indique si le LEDI Network IN fonctionne en adresse IP fixe entr e dans le champs IP address ou avec le protocole DHCP l identificateur DH...

Page 22: ...vous devez indiquer une passerelle gateway qui sera utilis e pour sortir du r seau local Without gateway Cochez cette case si vous n avez pas de passerelle sur votre r seau ou que vous ne souhaitez pa...

Page 23: ...ndication sur la raison du dernier red marrage du LEDI Network IN Protection de l acc s au site WEB Si vous souhaitez prot ger l acc s aux param tres du LEDI Network IN vous pouvez sp cifier un mot de...

Page 24: ...inateur identifi par son adresse IP Jusqu 5 adresses IP de traps Trap address peuvent tre sp cifi es ce qui permet de g rer les alarmes sur 5 ordinateurs diff rents Le nom du syst me SNMP sa localisat...

Page 25: ...SNMP pour acc der aux informa tions SNMP Un mot cl doit avoir 8 lettres au maximum System name Un nom que vous pouvez donner au LEDI Network IN Ce nom appara t dans la variable sysName de la branche...

Page 26: ...tre le mode de synchronisation utilis par le serveur ou s lectionn par le logiciel client NTP Il montre ainsi les serveurs d finis par l utilisateur ou d tect s par le logiciel Description Lapartiedro...

Page 27: ...yncronisation et les serveurs NTP utiliser La table suivante peut vous aider choisir les param tres les plus appropri s Mode Nb de serveurs NTP utilis s Description One server 1 Utilise un seul serveu...

Page 28: ...age est consid r comme une sortie et est pilot e par une carte d affichage Un LEDI Network IN peut contenir jusqu 4 cartes de sortie en plus de la carte d affichage Les cartes de sortie et d affichage...

Page 29: ...appliquer sur la sortie de la carte par rapport l heure UTC Vous pouvez sp cifier une politque de changement d heure DST appliquer sur la sortie de la carte par rapport l heure UTC L image ci dessus...

Page 30: ...on d tat Il y a deux parties importantes dans la MIB Une branche g n rale appel e System Cette branche est compatible MIB II Une branche priv e qui contient des informations sp cifiques au produit LED...

Page 31: ...t nnnnnn Vxx yy aammjj o xx yy est la version courante du logiciel aammjj est la date d mission du logiciel jj mm aa et nnnnnn est le num ro de s rie du produit ntpCliProduct Une description du produi...

Page 32: ...ctuellement les propri t s r seau ntpCliSyncMode Le mode de synchronisation actif actuellement Il peut prendre les valeurs suivantes Autodetect aucun serveur NTP n a t sp cifi et le produit essaye de...

Page 33: ...LEDI Network IN utilise le serveur de plus haut rang 10 Hardware La MIB d crit les cartes d tect es et leurs configurations Toutes les cartes de sortie et l afficheur sont connect s au m me bus de sor...

Page 34: ...ar l interface WEB Si la carte ne peut tre d sactiv e ce champs prend la valeur notapplicable 11 ntpOutBusCardTimeZone Fuseau horaire pour cette sortie Il est donn comme un offset par rapport au temps...

Page 35: ...types de sorties sont disponibles 1 Connexion pour tous les produits 1 1 Produits 230V et 115V AC type 0 L arri re du produit poss de une prise d alimentation standard une prise Ethernet RJ45 et un b...

Page 36: ...disponible en double sur cette sortie Voici une vue sch matique de la carte de sortie AFNOR IRIG B Le connecteur de sortie est localis sur la face arri re du rack comme ci dessous Voici les pattes du...

Page 37: ...en niveau RS 232 ou RS 485 Voici une vue sch matique de la sortie ASCII TOP Les connecteurs de sortie sont sur la face arri re du rack comme ci dessous La prise 4 points a le format suivant TOP Code...

Page 38: ...38 MDE LEDI NETWORK IN 4065V1 0 Le connecteur DB9 a le format suivant 5 4 3 2 1 9 8 7 6 GND TXD TX TX...

Page 39: ...trame Field Size Value Meaning STX 1 Un simple octet de valeur 2 qui signale le d but de la trame DAY 3 Le jour de la semaine en anglais MON pour Lundi TUE pour Mardi WED pour Mercredi THU pour Jeudi...

Page 40: ...40 MDE LEDI NETWORK IN 4065V1 0 2 Carte type B AFNOR IRIG B NFS87500 2 1 Format de la trame...

Page 41: ...41 MDE LEDI NETWORK IN 4065V1 0 Annexe B Format du code de sortie 2 2 Encodage des bits FRANCAIS...

Page 42: ...ar sortie 18V 62mA plus 7 mA par sortie 72V Environnement Temp rature de fonctionnement 5 50 C 41 122 F Temp rature de stockage 40 70 C 40 151 F Autonomie lectrique 4 heures sur les batteries internes...

Page 43: ...de s rie sur 6 chiffres nnnnnn La seconde ligne est la description du produit 9257 X opt Une ou plusieurs lettres une lettre par sortie A ASCII TOP B IRIG B AFNOR NFS87500 Une lettre qui indique le t...

Page 44: ...est une table que vous pouvez librement copier et distribuer Description de l installation vous pouvez utiliser cette table pour cr er une vue synth tique de toute votre installation Configuration de...

Page 45: ...WORK IN 4065V1 0 Annexe E Documents compl mentaires Vue r sum e de l installation Description de l installation Date d installation Nom de l installateur Description du produit Num ro de s rie Localis...

Page 46: ...ORK IN 4065V1 0 Configuration des appareils Description de l installation Date d installation Nom de l installateur Appareil Sortie Fuseau horaire et politique de changement d heure Annexe E Documents...

Page 47: ...47 MDE LEDI NETWORK IN 4065V1 0 NOTES FRANCAIS...

Page 48: ...ation 82 38 04877 38 GORGY TIMING RC 74 B 38 Toutes modifications d ordre technique ou esth tique peuvent tre apport es sans pr avis support gorgy timing fr SUPPORT TECHNIQUE depuis la France sur un p...

Page 49: ...49 MDE LEDI NETWORK IN 4065V1 0 USER GUIDE LEDI Network in ENGLISH...

Page 50: ...ronment you must dispose of this equipment in a collection site provided for this purpose separately from household waste Contact your reseller collec tion site or the competent lcoal authorities for...

Page 51: ...on 62 2 2 1 Introduction 62 2 2 2 Default configuration 62 2 2 3 Change the settings 62 3 FRONT DISPLAY INTERFACE 64 3 1 Start up conditions 64 3 2 Time display 65 3 3 Alarm condition 66 4 WEB INTERFA...

Page 52: ...R type cards ASCII TOP output 100 2 B and T type cards AFNOR IRIG B NFS87500 101 2 1 Frame format 101 2 2 Bit encoding 102 3 DCF and TDF time code description 103 APPENDIX C TROUBLESHOOTING 104 I made...

Page 53: ...in combination with the LEDI Network IN you greatly improve the ease of installation and use Jump directly to section 1 1 for quick installation 1 1 Quick installation This part contains the minimum...

Page 54: ...Gorgy Timing recommends you to fill in for each product its physical locali zation This is possible using the GTNetMng tool localized on the CD ROM For more information see part 31 2 1 2 Set up your p...

Page 55: ...ut Each card can be configured to output several local times This configuration is done through a WEB browser see part 32 1 3 Basics This part contains a description of the basic concepts of the produ...

Page 56: ...g figure shows how the evolution of the two clocks with or without drift The objective of the synchronization of a NTP client to a NTP server is to reduce as much as possible the drift and the offset...

Page 57: ...ary because of network load or NTP server load Worse the transmission time from client to server is generally not the same that the one from the server to client Actually on a large period of time the...

Page 58: ...red to leave this state Learning The NTP client software has found one or several Gorgy Timing auto detection ac tivated or works with configured servers In this state the software learns network prop...

Page 59: ...d the LEDI Network IN automatically uses a default IP address in the range 169 254 x y where x and y are between 0 and 255 The default DHCP identifier of the product is CRnnnnnn with nnnnnn the serial...

Page 60: ...k on the line related to the product you want to configure The following panel is displayed Set the network parameters and physical localization and click the Set button Name serial number and localiz...

Page 61: ...e DHCP name ntpin3 to your LEDI Network IN you can simply type ntpin3 in the address field of your WEB browser If you have several products to install on your installation it is highly recommended to...

Page 62: ...B type card AFNOR IRIGB TTL RS422 T type card ALARM G type card NTP server N type card You can freely use and copy the table Devices configuration in Appendix F Additional documents 2 2 2 Default con...

Page 63: ...ternet NTP server The NTP server card has to be configured by the same way than the NTP client of the LEDI Network IN Its default network configuration is DHCP mode with identifier SC nnnnnn with nnnn...

Page 64: ...N are not valid and are not dis played Then you can see the following texts When the device start all the dots of the displays are lightened During hardware initialization the following text is displa...

Page 65: ...sent and the LEDI Network IN is correctly synchronized on a server the current time of the server is permanently displayed The display alternatively shows time and date as shown below When displayed i...

Page 66: ...ndicates that the server currently used for synchronization does not reply or does not reply correctly In this case the LEDI Network IN tries another server The display alternatively shows time as des...

Page 67: ...your WEB browser as shown below and validate the input5 It takes about 20 seconds to load of the JAVA applet If the load fails it can be for one of the following reasons 1 The IP address is invalid 2...

Page 68: ...2 2 2 SNMP configuration of SNMP parameters 3 NTP diagnostic and configuration of the NTP software behavior 4 Output diagnostic and configuration of output cards and display The Set Up button updates...

Page 69: ...on about the product Network parameters Here are the different parameters IP mode Indicate if the LEDI Network IN works with a fixed IP set in the field IP address or use DHCP protocol the DHCP identi...

Page 70: ...o go outside local network Without gateway Check this box when you don t have a gateway on your network or don t want to use it Product information Here is a description of the product information are...

Page 71: ...fy a password This is done by enter the password twice in the area Enter password and Confirm password the same password in the two areas If you don t want to protect the parameters check the box With...

Page 72: ...to a SNMP browser localized on a computer identified by its IP ad dress Up to 5 IP Trap address can be specified that allows the alarm monitoring from 5 different computers Last the SNMP related name...

Page 73: ...must have 8 letter at the most System name A text that you can use to give a name to the LEDI Network IN This name appears in the sysName variable of the system branch of the MIB The initial value is...

Page 74: ...ization mode used by the server or selected by the NTP software It also shows the servers defined by the user or detected by the software Description The right part of this screen shows the current co...

Page 75: ...to indicate the synchroniza tion mode and the NTP servers to use The following table can help you to select the more appropriate parameters Mode of NTP servers used Description One server 1 Use only...

Page 76: ...rk IN can contain up to 4 output cards plus the display card The display and each output cards can be configured independently using the right cyan box When an output card is not present or in failure...

Page 77: ...are in the open state For AFNOR output the carrier is not modulated The ALARM output doesn t generate warning signal Time Zone The Time Zone is a time offset that can be added or subtracted from the...

Page 78: ...different alarm signals choose an alarm type no alarm synchronization failure power failure synchronization power failure then set the period and width of the signal Do the same for each alarm type E...

Page 79: ...ut card 4 3 1 Network and SNMP setup To configure network and SNMP parameters the NTP server output card provides the same WEB panels than the LEDI Network IN see below Please refer to parts 2 2 and 2...

Page 80: ...on of the different fields STRATUM level the stratum value to be stored in the NTP messages sends to the NTP clients Reference ID A 4 letters identifier that gives information about the time reference...

Page 81: ...r or TCP Time server Lock control This checkbox allows the user to control the lock state of the LEDI Network Enhan ced When checked the NTP server is locked and doesn t deliver NTP or output signal W...

Page 82: ...private branch that contains information specific to the LEDI Network IN product Private MIBs are described with MIB files Two MIB files are provided on the CDROM in the directory English LEDINETWORK...

Page 83: ...cription of the product It should be something like GT LEDI Network IN client nnnnnn Vxx yy yymmdd where xx yy is the current version of the software yymmdd is the release date of the software dd mm y...

Page 84: ...areState This field gives the current state of the NTP client software It can take one of the following values Idle the product has just started Autodetection no NTP server has been specified and the...

Page 85: ...the server ntpCliSyncSrvAccuracy Accuracy of the server as returned in the NTP frame something like 2 x se conds ntpCliSyncSrvUpAccuracy Gorgy Timing server only Accuracy of the server as returned dur...

Page 86: ...s indexed by its address 1 8 for output cards and 9 for the display Each entry has the following format ntpOutBusCardIndex Index of this entry i e card address This value can have a value from 1 to 8...

Page 87: ...Day Saving Time is in effect value summertime or not value winterti me If Day Saving Time is not activated this field has the value notapplicable ntpOutBusCardTotalOffset Indicate current total offse...

Page 88: ...calization in the MIB iso 1 org 3 dod 6 internet 1 private 4 enterprises 1 gorgy 8955 software 1 ntpSrv 3 5 2 1 Software information MIB for the NTP server outcard General organization This branch con...

Page 89: ...d that the NTP output is deactivated false 0 if the time code is present or the NTP server software can guarantee the accuracy NTP output is activated Tracking module information ntpSrvLockedOnSecurit...

Page 90: ...onds NTP server outcard this value is initialised to 65535 0 seconds Network dialog information statistics ntpSrvNbNtpRequests Total number of received NTP requests in fact all the requests received o...

Page 91: ...ent This value can change when the synchronisation is lost depending on the policy defined in the setup Moreover the default value can be changed through the setup ntpSrvLIValue Current LI value This...

Page 92: ...Failure Failure no more time code and the time base has no more autonomy 6 5 ntpSrvRescaled ntpSrvRescaling NTP server software is rescaled or is resca ling on its PPS source 4 ntpSrvSecurityLock NTP...

Page 93: ...of the product 1 Connection for all products 1 1 230V and 115V AC product type 0 The backside of the product has a standard power supply plug the Ethernet RJ45 plug and a RESET button as shown below...

Page 94: ...le twice on this output Here is a schematic overview of the AFNOR IRIG B output card TOP Time code Amplitude Modulator AFNOR IRIG B output 1 AFNOR IRIG B output 2 The output connector is localized on...

Page 95: ...Dual AFNOR IRIG B NFS87500 DCLS RS422 and TTL output T type This card has its outputs on a 4 points plug and a BNC connector The RS422 AFNOR code is available on the 4 points output The BNC connector...

Page 96: ...S 232 levels Here is a schematic overview of the ASCII TOP output The ASCII DB9 connector is localized on the backside of the rack and is shown below Connector pin out for RS232 Connector pin out for...

Page 97: ...time TOP or synchro power alarm TOP The 4 points plug has the following pin out Static Relay Outputs 1 and 2 Pin 1 Pin 2 without polarity Max switching voltage 350 V AC DC Max switching current 130 mA...

Page 98: ...dspeaker does not accept the VDC voltage To avoid the transistor destruction limit the input current to 30 mA i Vdc R 30mA TTL input command R External DC Power WaRNING VDC max 45 Volts 3 4 loudspeake...

Page 99: ...4065V1 0 5 3 Example of how to use the static relay output pins 1 2 R External DC or AC Power Supply WaRNING V max 60 Volts VCC 1 2 loudspeaker pulse WARNING You must ensure that mA R V i 130 APPENDIX...

Page 100: ...this frame Field Size Value Meaning STX 1 A single byte which value is 2 mark the beginning of the frame DAY 3 The day in the week in a human readable way MON for Monday TUE for Tuesday WED for Wedne...

Page 101: ...101 MDE LEDI NETWORK IN 4065V1 0 APPENDIX B OUTPUT CODE FORMAT 2 B and T type cards AFNOR IRIG B NFS87500 2 1 Frame format ENGLISH...

Page 102: ...102 MDE LEDI NETWORK IN 4065V1 0 2 2 Bit encoding The signal is modulated only on B card The T card output signal has TTL level...

Page 103: ...E H Indicates a seasonal changeover on the next hour HE Summer time HH Winter time P1 P2 P3 Parity bits APPENDIX B OUTPUT CODE FORMAT 0 10 20 30 40 50 minutes 2 4 10 20 40 80 P1 P2 P3 M 20 20 20 40 10...

Page 104: ...the device take automatically an address in the range 169 254 x y if it does not find any DHCP server Change your computer IP address in this range with a network mask of 255 255 0 0 I cannot open th...

Page 105: ...s 9999 Password gtmt Proceed to a Factory Default then Quit and save Refresh the WEB page 3 If the output is still missing open the device Check the black cables connections and the switchs configurat...

Page 106: ...one hour Remove the power supply Open the product with the screw driver the battery is located between the power supply card and the display card Disconnect the old battery with the screw driver Check...

Page 107: ...he signal on output Don t forget to put it OFF again after testing 3 Updating Firmware 3 1 Obtaining Firmware Firmware updates and releases notes for GORGY TIMING NTP devices can be down loaded direct...

Page 108: ...en Click on the Start button to extract all the files needed for the update When the extraction is terminated the tool GTNetMng is automatically started When all the files have been extracted correctl...

Page 109: ...address and click on the UPDATE button The update process start immediately When a problem occurs an error message is displayed Check the following points The product to update must be accessible thr...

Page 110: ...utput 18V 62mA plus 7 mA per output 72V Environmental Operating Temperature 5 to 50 C 41 to 122 F Storage Temperature 40 to 70 C 40 to 151 F Electrical autonomy 4 hours on internal battery 3 Autres sp...

Page 111: ...UPPLY 230VAC 50 60Hz 0 115VAC 50 60Hz 1 18 72 VDC 9 OUTPUT EXTENSION 4 MAXIMUM Alarm in case of mains cut or absence of synchronisation signal input G NTP SNTP TCXO oscillator N AFNOR NFS 87500 IRIGB...

Page 112: ...tallation Each document is a table that you can freely copy and distribute Installation description you can use this table to make a synthetic view of all your installation Device configuration you ca...

Page 113: ...113 MDE LEDI NETWORK IN 4065V1 0 Summarized installation view Installation description Installation date Who has done this installation Device description Serial number Localization ENGLISH...

Page 114: ...114 MDE LEDI NETWORK IN 4065V1 0 Devices configuration Installation description Installation date Who has done this installation Device Output Time Zone DST configuration...

Page 115: ...115 MDE LEDI NETWORK IN 4065V1 0 NOTES ENGLISH...

Page 116: ...0 Fax 33 4 76 30 85 33 email gorgy gorgy timing fr www gorgy timing com RADIO TIMING LEDI LEDICA HANDI are trademarks by GORGY TIMING Number of statement for training provider activity 82 38 04877 38...