WEB page is reachable, but the browser is unable to load it.
Open a TELNET session:
Telnet < ip address> 9999
password : gtmt
Proceed to a
“Factory Default”
, then
“quit and save”
. Refresh the WEB page.
aN OUTPUT IS NOT vISIBLE IN THE CONfIGURaTION WEB PaGE ?
1. Press ‘F5’ to refresh the WEB page, and go back to output panel. If the output is
►
still missing, see next point.
2. Open a TELNET session:
►
Telnet < ip address> 9999
password : gtmt
Proceed to a
“Factory Default”
, then
“quit and save”
. Refresh the WEB page.
3. If the output is still missing, open the device. Check the black cables connections
►
and the switchs configurations (see Appendix D – MAINTENANCE / Output card
switchs verification).
THE DEvICE STaY IN “COMMUTING” MODE ?
1. The device stays in this mode when it cannot reach any NTP server. Check that
►
the NTP servers are reachable on the network.
2. Open the NTP panel of the configuration WEB page and verify that the IP addres
-
►
ses of the NTP servers are correct. If in
“auto-detect”
mode, restart your device :
the auto-detection is done at start-up.