1.3 Technical Data BlueBox T4
Computer:
PC 104, 800 MHz
Operation system: Embedded Linux®
Main memory 512 MB
Display:
Touch panel 95 mm x 54 mm; 480 x 272 pixel; colour
Storage media:
Industrial NANDrive™
512 Mb; 2 GB
Mechanical data:
Housing dimensions:
280 mm x 170 mm x 90 mm (W x L x H)
Weight:
approx. 2.5 kg
IP code (housing):
IP65
Die-cast aluminium housing, powder coated
Colour:
RAL 5010
Voltage supply:
Nominal voltage:
24 VDC (18 V – 28 V)
1
Power supply:
Switch-on power:
T4: 51 W; TS und TC: 76 W
Operation power:
T4: max. 15 W; TS und TC: max. 18 W
additionally up to 45 W for CAN-bus modules powered by the BlueBox
2
additional up to 6 W with sensor power supply via the serial interface connection
Interfaces:
1x CAN
2x Relay output
contact load 48 V/0.5 A
1x USB (not TS and TC)
1x Ethernet 10 or 100 Mbit/s
1x RS-232 or RS-485 (half-duplex)
optional with 12 VDC power supply
2x current output 4 mA – 20 mA
2x Pulse input
3
switching current approx. 6 mA
measurement range up to 20 kHz
switchable to static
Modem (optional):
HSPA/LTE | ISDN | analogue
Ambient conditions:
Ambient temperature: Storage: -10 °C to +50 °C
Operation: -20 °C to +45 °C
avoid direct sunlight
Relative humidity:
≤ 90 % (annual average)
To protect the device and to ensure the proper functioning of the device, the specified ambient conditions
must be strictly adhered to!
1
The connected CAN-bus modules receive their power from the BlueBox. Some modules have a constricted input range, so
there is a input voltage tolerance of ± 10 %.
2
CAN-bus modules can also be supplied directly via the power supply unit.
3
see also
1.6 Notes on the Pulse Inputs
Article-No. 486 0004